ADEMCO 4110DL Instrukcja instalacji - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System bezpieczeństwa ADEMCO 4110DL. ADEMCO 4110DL 16 stron.

––––––––––––––––– ZONE RESPONSE TYPE CHARACTERISTICS ––––––––––––––––––
Zone Response Type
1 – Entry/Exit Burglary
3 – Perimeter Burglary
4 – Interior, Follower
5 – Trouble by Day/Alarm by
Night
6 – 24-Hr. Silent Alarm
7 – 24 Hr. Audible Alarm
8 – 24-Hr. Auxiliary Alarm
9 – Fire
10 – Interior w/Delay
–––––––––––––––––––––––––––WIRING GUIDELINES ––––––––––––––––––––––––––––
Wire Size
#22
#20
#18
#16
* Includes Keypads and alarm devices requiring separate power.
Example: If you have two motion detectors that draw a total of 44 mA, and you are using #20 AWG
IMPORTANT
Characteristics
Provides exit delay time when panel is armed in any arming
Provides entry delay when panel is armed in Away and Stay
only.
Provides an instant alarm when panel is armed in any arming mode.
Provides exit delay time when panel is armed in any mode.
Will only provide entry delay if an Entry/Exit zone is faulted first upon
entry. Otherwise, alarm will be instant.
Bypassed automatically when panel is armed in the Stay or Instant
mode.
Provides a trouble response if panel is not armed when zone is faulted.
Provides an instant alarm if panel is armed in any mode.
Provides a silent alarm to Central Station whether panel is armed or
disarmed.
Provides an audible alarm at the bell output and keypad whether
panel is armed or disarmed.
Provides an audible alarm at the keypad only. No bell output is
provided.
Provides a fire alarm when zone is shorted. Causes bell output to
pulse.
Provides a trouble response when zone is open.
Provides entry and exit delay times.
Bypassed automatically when panel is armed in the Stay or Instant
mode.
Wiring Run Chart For Devices* Drawing Aux Power From
The Control (12V+ & GND)
TOTAL CURRENT DRAWN BY ALL DEVICES CONNECTED TO A SINGLE WIRE
50 mA or less
500 ft (152m)
750 ft (228.6m)
1300 ft (396m)
1500 ft (457m)
wire, the distance from the control panel Aux + and - terminals to the last device can be up
to 750 ft.
The length of all wire runs for keypads must not exceed 1500 feet (457m)
when unshielded quad conductor cable is used (750 feet if shielded cable is
used). This restriction is due to the capacitive effect on the data lines when
quad cable is used.
Transformer Wiring Table
Distance of Transformer
From the Control Panel
Up to 50 feet
50–100 feet
100–250 feet
RUN
100 mA
300 mA
250 ft (76m)
80 ft (24m)
380 ft (116m)
130 ft (39.6m)
650 ft (198m)
220 ft (67m)
1000 ft (305m)
330 ft (100.5m)
Wire Gauge
To Use
# 20
# 18
# 16
-7-
mode.
modes
500 mA
50 ft (15m)
80 ft (24m)
130 ft (39.6m)
200 ft (70m)