MATERIAL % - This is the percentage of ZycoTherm to be added to the AC.
AC% - Your AC% is manually typed in. This button may alternatively say "AC TPH" if an
analog signal is connected. AC TPH can only be achieved using an analog signal from the
plant and can not be manually entered from this screen.
THP – This button is the plant Tons Per Hour target. It can either be manually entered here or
entered through the use of an analog signal with proper setup. It is recommended to set up the
analog signal to represent the AC TPH and not use the manual option.
SUB – T & TOTAL – This is a running tally of the material that has been run. They can be set
independently depending on the needs of the plant.
NO FAULTS – This button will indicate if there are any faults with the pump. Faults include:
High/Low/No Flow – Drive Fault – E-Stop @ Pump – E-Stop @ Control – No Disk @ Pump –
and Replace Tote. All warnings will turn this button red with Yellow lettering describing the
warning.