Here need to setup only based on linking network. Operations: ENT + press "
ENT】 → "X X X X": 4 digits, you can set 0000~9999. Default set before shipping is at ransom.
【Upload status】:
This is for uploading Arm/Disarm/Alarm information to the Managing Centre. Operations:【ENT + "▲▼" + ENT】 → "▲▼"
choose "yes" or "no" for upload or not upload. The defaulted is "No".
【CutWire Alarm】:
This is for PSTN (landline) only. ENT + CutWire Alarm, press "▲▼" to choose YES or NO. If choose "Yes",it will alarm when
telephone line is not connected. Default set before shipping is "Yes".
【Zone Attribute】:
Here is for setting【Zone number】,【Zone type】, 【Alarm Type】【Bypass Zone】 &【Entry Delay Set?】.
---【Zone number】:
Here has 39 zonesfor your settings. 2 dedicated zones for remotes(Supports up to 4 remotes or wireless keypads per zone).29
wireless zones(Each zone supports up to 4 sensors) and 8 optional wired zones. Each zone needs to setup "Zone Type", "Alarm
Type" ,"Bypass Zone" & "Entry Delay".
Table 3: "Zones Number" setting
Zone
Sensor Type
Number
00、01
02 ~ 10
Wireless sensors
11 ~ 20
21 ~ 30
31 ~ 38
Wired sensor
【Zone Type】:
You can see "2", "1", "0".( "2" mean motion zone, "1" means perimeter zone, "0" means emergency zone)
Press "▲▼" to choose the one you desire to setup, then press ENT to confirm your settings.
【Alarm Type】:
【ENT + Alarm Type+ press "
below table. )
Table 4: Wireless/wired sensor code
Code
00
Sensor
Button0
Name
Code
08
Sensor
IR
Name
Table 5: Default set before shipment
Wireless sensors
Zone Number
【Bypass Zone】:
This setting is for make zones enable or disable. Here has "Yes" & "No" for your alternatives. "Yes" means make this zone‟s
sensors silent, "No" means keep this zone‟s sensors working. Press "▲▼" to choose "Yes" or "No", then press ENT to confirm
your settings.
【Entry Delay Set?】:
Zone
Type
——
Emergency zone
Perimeter zone
Motion zone
——
" button to delete old record + X X + ENT】→ "X X": 2 digits. Alarm type code. 2 digits.( See
01
02
Button1
Gas
09
10
Perimeter
Perimeter
Wireless
Wireless door
remote
sensor
00
11
Applicable sensor names
Wireless remote & Wireless Keypad
Wireless Smoke Alarm,
Wireless Gas Alarm& Panic button etc.
Wireless Door/Window Sensor &
Wireless Curtain PIR etc.
Wireless Wide-Angle PIR Motion Sensor etc.
31,32,33 are Perimeter zone
34,35 are Motion zone
36,37,38 are Emergency zone
03
04
05
Smoke
Door
Window
11
12
13
Motion
Sensor
Sensor
Wireless
wide-angle
PIR sensor
21
" button to delete old record + X X X X +
Each zone
support up to 4
sensors
See Table 4:
Wireless/wired
sensor code
06
07
Glass
Motion
14
15
Sensor
Sensor
(doorbell)
Wireless gas
Wireless
sensor
smoke sensor
02
03
Notes
20