Do not run the pump more than necessary without
flow. "Dry running" can cause overheating and pump
damage.
•
To avoid personal injury, turn the pump off and
disconnect from power before repair or service.
•
For your protection, thoroughly flush the pump before
cleaning or repair.
When you receive your pump, examine it for visible
damage. If any items are damaged or missing, please
contact your distributor.
INSTALLATION
For proper installation, your pump requires a hose, nozzle
and suction pipe. Kits are available from the factory and
are listed as accessories on the Illustrated Parts List.
Used pumps must be flushed and cleaned before
installation as outlined in the Maintenance Section.
To prevent leaks, seal all connecting threads with 3 to 4
turns of thread tape during installation.
Before installing the pump, install the suction pipe into
bung adapter on the pump. Tighten the suction pipe into
the bottom of the bung adapter until only three threads
are visible.
Installing Pump
The pump has a 2-inch NPS bung adapter with gaskets
installed at the inlet end.
After installing the suction pipe into the bung adapter,
insert the suction pipe into the tank opening and tighten
the pump securely. Make sure the bung adapter threads
are not cross-threaded. (Figure 1)
Install Hose and Nozzle
If installing accessories such as meters or filters, do
so before installing the hose and nozzle. Follow the
manufacturer's instructions.
CAUTION
Make sure any hose and nozzle used are compatible
with DEF.
After sealing threads, hand-tighten the hose into the
outlet until snug. Hand-tighten the nozzle to the hose.
Using fluids other than those for which the pump was
designed could lead to serious personal injury and void
the warranty.
The pump is approved for Diesel Exhaust Fluid only.
Do not use with gasoline, diesel, other flammable
fluids, or micro-encapsulated fluids.
When handling fluids, always wear protective
clothing such as goggles, gloves and respirators,
as instructed by the fluid manufacturer.
Clean any spills from the system exterior as they occur,
following fluid manufacturer's instructions.
Before Each Use
1. Keep pump exterior clean to help identify leaks.
Before each use, inspect for leaks around seals or
connections.
2. Check for leaks under the pump housing. A small
drain hole relieves any fluid which bypasses the
motor shaft seal. (Figure 2) If any leakage is found
here, replace the motor shaft seal using instructions
in the Repair Section.
Figure 1
3. Make sure hoses are in good condition and
connections are tight.
4. Make sure the work area is dry.
Electrical Connections
PA-120DEF:
This pump is designed for use with GFCI protected, 115-
volt power. Do not attempt to install or operate the pump
with 12-volt, 24-volt or 230-volt power.
Use only three-prong, grounded connectors. Do not use
two-prong connectors or adapters. Inspect power cords
regularly and replace if signs of wear are evident.
OPERATION
WARNING
WARNING
Figure 2
3