2gig Technologies 2GIG-FT6-345 Instrukcje instalacji
Przeglądaj online lub pobierz pdf Instrukcje instalacji dla Czujniki bezpieczeństwa 2gig Technologies 2GIG-FT6-345. 2gig Technologies 2GIG-FT6-345 2 stron. Flood and temperature detector
2GIG-FT6-345
FLOOD AND TEMPERATURE DETECTOR
INSTALLATION INSTRUCTIONS
The 2GIG-FT6-345 is a fully supervised, one-way 345 MHz detector. It will detect wet
or dry floor conditions as well as the ambient temperature. The detector reports wet/
dry conditions and when specific temperature thresholds are exceeded.
Flood Conditions
Once the detector probe detects the presence of water, the integral transmitter will
immediately send a loop 3 wet alarm transmission to the panel. The detector will also
send a restore (dry) report when the presence of water is no longer detected. The
detector is capable of detecting clean or dirty fresh water, salt water and tap water.
The 2GIG-FT6-345 utilizes a unique design that can detect leaks dripping onto its
top or if there is water under the device. This dual sensing technology is perfect for
placement under P Traps or hoses that may leak, giving a warning just as the leak
starts. If a leak occurs at a different location, it will also be detected when the water
is sensed under the device.
Temperature Conditions
Heat:
1. If the temperature is more than 95° F (35°C) for three (3) minutes, the detector
will send a loop 2 transmission.
2. If the temperature is less than 95°F (35°C) for three (3) minutes, the detector
will send a loop 2 clear.
Cold:
1. If the temperature is less than 41°F (5°C) for three (3) minutes, the detector will
send a loop 1 transmission.
2. In the temperature is more than 41°F (5°C) three (3) minutes, the detector will
send a loop 1 clear.
Contents
Verify that the package includes the following:
• 1 — 2GIG Flood/Temperature Detector
• 1 — 3V CR123A Lithium Battery (Installed)
• 1 — Double sided adhesive tape
Figure 1. Temperature/Flood Detector Contents
DOUBLE SIDED ADHESIVE TAPE
LITHIUM BATTERY
1 Copyright © 2018 Nortek Security & Control
Replacing Battery
1. Open Detector Case (as shown in Figures 2 and 3).
2. Remove old battery, and dispose of properly
3. Install new battery.
4. Close Detector Case.
Grip the base of the detector case. Turn the top cover counter-clockwise to align the
dots, then separate the detector case.
Figure 3. Installing New Battery
Installing Water Detector
The 2GIG-FT6-345 Flood and Temperature Detector can be easily placed in any
location. If placed specifically under a potential leak source, use the included optional
double sided adhesive tape to secure it in the desired location (see Figure 4).
Figure 4. Suggested Installation Locations
Place the detector in locations
that have the potential of
water leaks or flooding.
For example:
• Under the sink pipes
• Adjacent to water heaters
• Adjacent to toilets
• Adjacent to bathtubs or
showers
• Under or near your
dishwasher
• Near washer and dryer
DETECTOR
(following state regulations).
BATTERY TERMINAL
NEGATIVE (-)
DETECTOR
ALIGN DOTS
Figure 2. Opening the Detector Case
BATTERY TERMINAL
POSITIVE (+)
WATER