Dynafile 14010 Podręcznik - Strona 3
Przeglądaj online lub pobierz pdf Podręcznik dla Narzędzia Dynafile 14010. Dynafile 14010 12 stron. Air tool
WMV-Dresden, Ersatzteilservice für Elektrowerkzeuge, Motor- und Gartengeräte
Important: A Preventative Maintenance Program is recommended whenever portable power tools are used.
• Use only genuine Dynabrade replacement parts to insure quality. To order replacement parts, specify Model #, Serial # and RPM
of your air tool.
• It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility
of misuse due to unclean air, wet air or insufficient lubrication. Dynabrade recommends the following: 11405 Air Filter-Regulator-
Lubricator (FRL) – Provides for air pressure regulation, two stage filtration of water and contaminants.
Operates 40 SCFM/1,133 LPM @ 100 PSIG with 3/8" NPT female ports.
• Dynabrade recommends one drop of air lube per minute for every 10 SCFM (example: if the tool specification states 40 SCFM, set the
drip rate on the filter-lubricator to 4 drops per minute). Dynabrade Air Lube (P/N 95842: 1 pt 473 ml) is recommended.
Routine Preventative Maintenance: Check free speed of Dynafile
• Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids,
esters, ketones, chlorinated hydrocarbons or nitro carbons.
• DO NOT clean or maintain tools with chemicals that have a low flash point (example: WD-40
• A Motor Tune-Up Kit (P/N 95600) is available which includes high wear and medium wear motor parts.
• Air tool labels must be kept legible at all times, if not, reorder label(s) and replace. User is responsible for maintaining specification
information i.e.: Model #, S/N, and RPM. (See Assembly Breakdown)
• Blow air supply hose out prior to initial use.
• Visually inspect air hoses and fittings for frays, visible damage and signs of deterioration. Replace damaged or worn components.
• Refer to Dynabrade's Warning/Safety Operating Instructions Tag (Reorder No. 95903) for safety information.
After maintenance is performed on tool, add a few drops of Dynabrade Air Lube (P/N 95842) to the air line and start the tool a few times to
lubricate air motor. Check for excessive tool vibration.
Handling and Storage:
• Use of tool rests, hangers and/or balancers is recommended.
• Protect tool inlet from debris (see Notice below).
• DO NOT carry tool by air hose.
• Protect abrasive accessories from exposure to water, solvents, high humidity, freezing temperature and extreme temperature changes.
• Store accessories in protective racks or compartments to prevent damage.
Model
Motor
Motor
Sound
Number
HP (W)
RPM
All Models
.5 (373)
20,000
77 dB(A)
Additional Specifications: Air Inlet Thread 1/4" NPT • Hose I.D. Size 3/8" or 10mm • Air Pressure 90 PSIG (6.2 Bars)
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality
pneumatic motors can most often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained
in the air supply into motor bearings causing early failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency
and power. Our warranty obligation is contingent upon proper use of our tools and cannot apply to equipment which has been subjected to
misuse such as unclean air, wet air or a lack of lubrication during the use of this tool.
LIFETIME WARRANTY
To validate Dynabrade Lifetime Warranty, you must register each tool at: www.dynabrade.com. Registration of each tool
at website is required. Dynabrade will not honor Lifetime Warranty on unregistered tools. Please view the entire Lifetime
Warranty Policy at : www.dynabrade.com.
REFERENCE CONTACT INFORMATION
American National Standards Institute (ANSI)
25 West 43 Rd St., 14th Floor • New York, NY 10036 • Tel: 1 (202) 293-8020
Compressed Air & Gas Institute
1300 Sumner Ave. • Cleveland, OH 44115-2851
Tel: 1 (216) 241-7333 • Fax. (216) 241-0105
European Committee for Standardization
Rue de Stassart 36 • B - 1050 Brussels, Belgium
Maintenance Instructions
Machine Specifications
Abrasive Belt Size
Level
Inch (mm)
1/8-1/2 (3-13) W x 24 (610) L
®
using a tachometer.
®
Maximum Air Flow
Max. SFPM
CFM/SCFM (LPM)
4/31 (878)
5,800 (1,762)
Notice
International Organization of Standards
Case postale 56 • CH-1211 Geneva 20
Tel: + 41 22 749 01 11 • Fax: + 41 22 749 09 47
Government Printing Office
Superintendent of Documents • Attn: New Orders
P.O. Box 371954 • Pittsburgh, PA 15250-7954
Tel: 1 (202) 512-1803
3
).
Weight
Length
(SMPM)
Pound (kg) Inch (mm)
3.1 (1.4)
14.6 (371)
Height
Inch (mm)
4.6 (116)