Please read this entire manual before attempting to install this system.
This system should only be installed by a professional automatic gate installer or access control
specialist installer.
It is recommended that the system be range tested on site BEFORE being fully installed.
Before installing this system, you need to be sure that the range of the system will be sufficient.
The transmitter and speech unit can be powered up, call button pressed, and then check that the
handset will ring from all areas in which it will be used.
Up to 200m / yards
.
Speech
panel
Tip: For longer range installations, locate the handset close to the front of the property, near a
window if possible. Concrete walls can reduce the open-air range of 400 metres/yards by 30-50%
per wall.
CAUTION!
Competent person only!
24v dc PSU
TIP: Most technical calls received are due to installers using CAT5 or alarm cable to power
the unit. Neither are rated to carry enough power (1.2 amp peak). Please use following
cable...
Up to 2 metres (6 feet) – Use minimum 0.5mm
Up to 4 metres (12 feet) – Use minimum 0.75mm
Up to 8 metres (24 feet) – Use minimum 1.0mm