GAI-Tronics 341-001 Podręcznik użytkownika - Strona 9
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Telefon GAI-Tronics 341-001. GAI-Tronics 341-001 16 stron. Div. 2 industrial telephones
M
226-002, 341-001,
ODEL
Model 341-001
Mounting and wiring of the Model 341-001 must be in accordance with Div. 2 installation standard
practices.
1. Remove the four front panel screws using a standard Phillips screwdriver, and remove the front panel
assembly and set aside.
Figure 5. Model 341-001 Outline Drawing
4. Connect the telephone cord's modular connector to the incoming subscriber line using the appropriate
mating connector or connect the incoming line directly to the terminal strip. See Figure 6.
5. Replace the front panel assembly, and secure with the four front panel screws.
6. Check for proper telephone operation by calling to and from another telephone.
e:\standard ioms - current release\42004 instr. manuals\42004-339f.doc
07/14
351-001 D
. 2 I
AND
IV
NDUSTRIAL
T
ELEPHONES
2. There are four mounting holes in
the rear enclosure. Mount the
enclosure to the wall using either
four 1/4-20 machine screws with
nuts and washers, or #14 wood
screws of appropriate length for the
mounting surface. Refer to Figure
7.
3. Enter the rear enclosure with
telephone wiring per accepted Div.
2 standards.
Figure 6. PCBA Connection
P
. 42004-339F
UB
8 of 14
P
AGE