2. Select the appropriate sized gland:
Use the smaller gland for cables diameters 4 - 7mm.
Use the larger gland for cable diameters 8 - 13mm.
3. From the outside of the case, insert
the selected gland into the threaded
cable entry hole and tighten, so that its
sealing washer is compressed against
the enclosure surface.
4. Proceed with chosen mounting method
below
As standard, The telephone is supplied with a pole mounting kit 100-02-0208-
001, but no glands.
4.3. Wall mounting
1. Using a suitable tool, punch out 4 holes in the rear enclosure, taking
care not to damage or dislodge the plastic bushes. Only four of the
eight holes are required - the outer ones are recommended. The
inner holes are provided to be compatible with older-style mounting
posts, and should be left intact if not used. If the inner holes are
used they must be fitted with the supplied plastic bushes.