DayTronic 3000PLUS Instrukcja obsługi - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe DayTronic 3000PLUS. DayTronic 3000PLUS 20 stron. Panel meter, frequency conditioner module
Również dla DayTronic 3000PLUS: Instrukcja obsługi (20 strony)

DayTronic 3000PLUS Instrukcja obsługi
S
PECIFICATIONS
Analog Filters: 0.2, 2, 20, 200, or 2000 Hz, selectable when
the 3000PLUS meter is configured
Status Indicator Light: Green/Yellow/Red; indicates module
input and communications status (see Section 1.D)
Table 1
Model 5D40 Full-Scale Ranges (Nominal),
with Corresponding Accuracies and
Common-Mode Ranges*
(Accuracy given as % of full scale overall
expected maximum error, following calibration)
Range
(Hz , f.s.)
Accuracy 0.1% to 36% of FS +/- 0.04%. Above 36% FS +/- 0.02%.
200
300
400
500
750
1000
1500
2000
3000
4000
6000
8000
10000
15,000
20,000
30,000
40,000
60,000
80,000
100,000
150,000
200,000
300,000
400,000
* See Table 2 in Appendix B for the "practical" ranges that apply to
the 5D40 RANGE (RNG) setting.
3000PLUS
(
'
)
CONT
D
5D40 I
WITH
NSTRUCTION
1. I
NTRODUCTION
M
. SB.3
ANUAL V
3KP40 - 1.4