DayTronic 3770 Instrukcja obsługi - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe DayTronic 3770. DayTronic 3770 16 stron. Dc strain gage panel meter

Model 3770
3
C
O N T R O L S
Display Range and Decimal Point Selection
Switch 1 - selects decimal point for position X.XXXXX
Switch 2 - selects decimal point for position XX.XXXX
Switch 3 - selects decimal point for position XXX.XXX
Switch 4 - selects decimal point for position XXXX.XX
Switch 5 - enables dummy zero display digit XXXXX
Switch 6 & 7 - selects Display Full Scale Range.
Range will equate to an analog output value of ± 5 Vdc or ± 10 Vdc per Analog Control switch placement.
Selection is set for 1 count in 5000, 2 counts in 10000 and 5 counts in 20000.
Analog Zero and Span Adjustments
Coarse Zero - 22 Turn potentiometer adjustment for balance control of analog offset signal
Fine Zero - 25 Turn potentiometer for fine balance control of analog offset signal
Coarse Span - 22 Turn potentiometer adjustment for analog control of gain
Fine Span - 25 Turn potentiometer adjustment for analog control of fine gain
DC STRAIN GAGE PANEL METER
0
Page 7