Spinner Replacement Procedures

The Bulb Eater® spinner assembly should be changed every 10 drums or as needed.
Gloves and eye protection should be worn while changing the spinner.
With the Bulb Eater
®
on a clean, empty drum:
1.
Carefully stand the Bulb Eater
2.
With an allen wrench, loosen the set screw holding the spinner on the motor shaft.
3.
Slide off the old spinner and replace with new spinner in the same position.
4.
Tighten the set screw fi rmly to secure the spinner to the motor shaft.
Use these tools to adjust the open lid and full drum sensors.
If the "Open Lid" light remains on while the lid is closed, use the 1/8" hex wrench to adjust the lid
sensor to extend 3/16" from the sensor housing.
If necessary, use the included screwdriver to adjust the sensitivity on the full drum sensor. The factory
setting is minimum sensitivity. (Remove control box cover to access sensitivity screw. Reseal bottom of
control box when replacing)
Sensor set screw (w/1/8" hex wrench)
800.909.9709
www.aircycle.com
®
on edge.
Adjusting the Lid Sensor
(use light pressure)
3/16"