DynaGen ES53 Instrukcja instalacji i obsługi - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Jednostka sterująca DynaGen ES53. DynaGen ES53 18 stron. Control module
Operating VDC limits:
Standby current draw:
Operating current draw:
Reverse polarity protected:
Speed sensing input accepts:
Speed sensing maximum rating:
Operating temperature range:
Operating humidity range:
Fuel & Crank contact output:
Annunciation outputs:
Lamp Test terminal:
Actual unit weight:
Shipping weight:
Unit dimensions:
Shipping dimensions:
Installation and User Manual for the ES53 Control Module
SPECIFICATIONS
(3.3VDC min.- 30VDC max.)
12mA at 12VDC (12mA at 24VDC)
140mA at 12VDC (80mA at 24VDC)
Internal protection will prevent damage to unit under a
reverse polarity condition. Re-connect power leads
properly, and normal operation will resume.
Generator AC output directly
Withstands Line voltage (300 V.A.C.)
O
O
C ⇒ +85
-40
C
0 ⇒ 95% non-condensing
10 Amps max. each Continuous
Sourcing (+bat) output
Sourcing (+bat) outputs (300ma max. per output)
Close to + Battery to test LED's
0.67 lb. (0.30kg)
1 lb. (0.45kg)
3.302" x 3.342" x 1.8"
4" (10.16cm) x 4" (10.16cm) x 3" (7.62cm)