Appendix

C - Diagnostic Tools

The receiver provides several diagnostic tools from within the
Diagnostics Menu (Menu 8). This section details the function of
each tool and its use.
Navigating To Diagnostics Menu
a. Press PREV to navigate to Menu 8
b. Press SET to display the menu of available functions.
c. Press PREV or NEXT to cycle through diagnostic tools.
d. Press SET to select.
Menu 8.1 Test Inputs
This tool is used to view the state of the control inputs. When
selected, a screen is displayed
of each input. If the name of the input is in upper case or number
in the bracket, then the input is active. Conversely if the input is in
lower case and [---] dash in the bracket, then the input is inactive.
For normal operation, all inputs should be inactive. When finished,
press EXIT.
Menu 8.2 Test Transmitters (Tx'ers)
This tool is used to test receiver/transmitter functionality. When
selected, a screen is displayed which prompts for a transmitter
button to be pressed
(Fig. C.3)
are to be displayed.
The opener will then beep each time a transmission is received. If
the transmitter button is stored in the controller memory and has
a function assigned to it, a second screen will be displayed that
shows the transmitter details along with the button pressed
(Fig.
C.4). The example shows the case where transmitter number
14 is activated by button 4. Note ID is selected for display.
Menu 8.3 Display History
The opener keeps a record of the last 64 events that have taken
place. The events include the type of drive cycles executed,
obstruction detection, various faults, power failures etc. When this
tool is selected, the screen displays the last event that occurred
(Fig.
C.5). Press NEXT or PREV to view each event. The "EVENT#"
field shows the sequence of the events, with (1) being the first and
(64) being the last. The example shows that the last event was a
close cycle which succeeded in closing the door. When finished
viewing the events, press EXIT.
Menu 8.4 Memory Usage
This tool displays the number of transmitter store locations used
(Fig. C.6).
and the number free
Menu 8.5 Console Test
The tool allows to test the console buttons and the beeper.
16
MegaCode
Receiver Installation Instructions
®
(Fig. C.1).
(Fig.
C.2) which indicates the state
and whether ID or serial numbers
MENU 8
Diagnostics
PRESS
DISABLE: ....
TRIGGER: ...4
PRESS TX'ER!
<—/—> Shows ID/SN
3 I
AB SMITH
D
›ON OFF OFF OFF
3 F= M_1
Event#
64
Used =
15
Free =
496
Fig C.1
Fig C.2
Fig C.3
PRESS
Fig C.4
Fig C.5
Fig C.6