Automatic Technology Australia GDO-8 v1 EasyRoller II Instrukcja instalacji - Strona 12
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Otwieracz drzwi garażowych Automatic Technology Australia GDO-8 v1 EasyRoller II. Automatic Technology Australia GDO-8 v1 EasyRoller II 20 stron.
6.3 SETTING LIMITS VIA REMOTE CONTROL
NOTE: The opener is factory preset for installation on the
RIGH HAND SIDE. When the opener is mounted on the left
side of the door the opener will travel in reverse.
1. Press button 4, the door will start closing. If the door starts
to open - press the Operate button (Fig. 10) within two
seconds. Press button 4 again - the door should now close.
Release the button once you are 1 to 2 cm from your desired
closed limit position.
2. Press button 3 for two seconds to switch to slow inching
mode.
3. Press button 4, each press will enable you to inch the door
to your desired closed position.
4. Once you are happy with the position press button 2, to
store the closed limit position into memory.
5. Press button 1, the door will start opening. Release the
button once you are 1 to 2 cm from your desired open limit
position.
6. Press button 3 for two seconds to switch to slow inching
mode.
7. Press button 1. Each press will enable you to inch the door
to your desired closed position.
IMPORTANT WARNING: Please be aware that the garage
door will start closing automatically once step 8 is
performed. The door will also automatically re-open after
fully closing with a short pause between the cycles.
8. Once you are happy with the position press button 2, to
store the open limit position into memory.
The door will now automatically close to its limit position then
fully open to calculate the safety obstruction forces (ISS).
Please be aware of the above warning.
7. RESETTING DOOR LIMITS POSITIONS
The door limit positions can be deleted for new positions by
following the steps below:
1. Press and hold the Minus button (Fig. 10) for six (6) seconds
until you hear three beeps and the red Close Limit LED
starts to flash. Release the button.
2. Follow STEP 6.3 above to set new travel limit positions.
Important: Their is no need to re-code the transmitter used
for setting the limit positions. After the limits are set the
transmitter will automatically reset to normal operation.
Go to STEP 8 and test the Safety Obstruction Force.
SETTING LIMITS
INCH CLOSE
BUTTON 4
12
INCH OPEN
BUTTON 1
FIG. 10
FIG. 11
SET
BUTTON 2
SWITCH
BETWEEN FAST
AND SLOW
INCHING
BUTTON 3