IMPORTANT
If the AirCycler® was installed in your home as a ventila-
tion controller, Do Not Disable it.
4.50 in.
11.5 cm
In the past, homes depended on natural leaks for ventila-
tion. Today energy efficient homes are built so that
natural ventilation and leaks are reduced. Inadequate
ventilation can increase indoor air pollutants to harmful
levels. Indoor air is typically 5 to 10 times more pol-
luted than outside air. Controlled ventilation provides
adequate air flow to the home without compromising its
efficiency.
SAFETY CONSIDERATIONS
Read and follow manufacturer's instructions carefully.
Follow all local electrical codes during installation. All
wiring must conform to local and national electrical
codes. Improper wiring or installation may result in
personal injury or product and property damage.
INSTALLATION CONSIDERATIONS
The AirCycler® STAT does not require batteries. It does
require 24 VAC (R and C terminals) to be connected for
proper operation. The AirCycler will not operate without
these two connections.
The wires (R, C, W, G & Y) from the air handler to the
AirCycler® Some thermostats do not require a (C)
connection. The AirCycler requires a (C) for power , which
needs to be wired to the furnace.
Key:
C- Common
R - 24 VAC Power
W - Heating
Y- Cooling
G - Fan
V - Vent
TROUBLESHOOTING
Problem: Blank Display on the AirCycler®
Solution Check:
1.
The furnace has power
2.
Confirm the furnace is providing 24 VAC to the
AirCycler®
3.
Verify wiring conforms to wiring diagram
4.
Make sure top is firmly seated in the base
3.50
Problem: AirCycler® turns furnace fan on and off, but
9 cm
the motorized damper does not cycle.
Solution Check:
1.
Verify that the AirCycler® is providing a 24 VAC signal
to the motorized damper
2.
Verify that 24 VAC motorized damper is operational by
powering directly with a 24 VAC signal
3.
Verify continuity in the wiring between the damper
and the AirCycler®
1.30 i
3.4 cm
The Smart Controller
411 Plain Street
Marshfield, MA 02050
1-877-326-2668
781-834-1601 (Fax)
www.AirCycler.com
The Smart Controller
AirCycler® STAT
Instructions
www.AirCycler.com
1 - 877 - FAN-CONTrol
INTRODUCTION
The AirCycler® STAT is a single set point thermostat
and a furnace fan timer. By operating the furnace fan
periodically the AirCycler® improves indoor air quality
and thermal comfort. The furnace fan circulates and
filters indoor air. The AirCycler ® enables the furnace
fan to operate more consistently with programmable
ON and OFF times.
Benefits
• Mixes and circulates indoor air
• Eliminates stagnant air
• Creates even temperature and humidity levels
• Filters indoor air consistently
• An economical alternative to continuously
running the furnace fan
APPLICATIONS
Digital Programmable Furnace Fan timer
The AirCycler® automatically turns the furnace fan
on for a set period of time only when it detects the
system has been inactive for a set period of time.
Ventilation
By adding a fresh air source to the return side of the
air handler, the existing HVAC system can be used
to provide ventilation. The AirCycler® enables this
ventilation system to work properly.
The AirCycler® STAT also has an output to operate
a motorized outside damper that limits excessive
ventilation. (
Motorized dampers sold separately,
normally closed, power open 24 VAC)