Przeglądaj online lub pobierz pdf Instrukcje instalacji i instrukcja obsługi dla Otwieracz do bram Automatic Technology Australia Elite. Automatic Technology Australia Elite 20 stron. Swing gate opener with remote control

Gate does not open and/or close
Gate re-opens when closing or stops when opening
Remote transmitter not functioning
Gate or opener requires a service
DIVE UNIT
Motor:
24 volts DC
Speed:
Drive arm/motor speed is adjustable in the control box
Size:
135mm wide, 290mm high and 230mm deep
Weight:
13kgs including arms
ELECTRONIC CONTROL BOX
Input Voltage:
Output Voltage:
Transformer Rating
Control System
Wiring System
External Box
Transmitter/Receiver
Size
Weight
The specifications above are approximate only.
ATA reserve the right to alter specifications at any time without notice in accordance with the Company's policy of continuous product development.
FA U LT S A N D R E M E D I E S
Check that Control Box is plugged into mains power.
Check that motor is engaged for automatic operation.
Check all wiring from motor and microswitches to the control board are
sound.
Check obstruction overload sensitivity adjustment (See Page 12, step 7)
Check for obstructions.
Disengage the drive unit to manual (see page 7) and check the gate is in
good working order (see page 6 step 1.1 & 1.2).
If a P.E. beam is fitted ensure it is clear of obstructions or dirt on the lense
New transmitters must be coded to the receiver (refer to page 16).
Check/change the battery in the transmitter.
Having the antenna behind a structure (gate or fence) or out of sight may
reduce optimal range/reception.
Interference from external/outside sources such as baby monitors, or radio
transmitter etc. The best solution is to remove the source causing the in-
terference.
Contact the installer of the opener or local ATA distributor for service.
They will be able to inspect, reset, service, adjust or repair the gate and
opener as necessary.
S P E C I F I C AT I O N S
240 volts/50Hz AC
24 volts DC from control board
24 volts AC, 100VA
Microprocessor control unit
Surface mount technology circuit board
Via on board terminal blocks
Weatherproof box when used with mounting kit and cable gland, IP56 rated
ATA model hand held transmitter 4 buttons, code hopping type, 9 VDC batteries included
ATA model receiver two channel code hopping type with over 4.29 billion codes
and 27 transmitter code store capacity. The transmitter frequency is 433.92 MHz.
190mm wide, 240mm high and 100mm deep
4Kgs
Page 18