Battery Replacement
Do not replace the battery while power is applied to the VertX EVO Controllers. Remove
the cover.
Insert the battery (with the + (positive) side facing upwards) under the prongs, lowering
the opposite side into place. Reinstall the cover.
To remove the battery, remove cover, lift the side opposite from the prongs first and
slide the battery out of place away from the prongs. Reinstall the cover.
Network Defaults Jumper
The Network Defaults Jumper requires that someone with physical access to the V1000, place a jumper over the
Debug port while the controller is rebooting, as detailed below. The controller reconfigures its network settings to the
factory defaults when the jumper is on the Debug port during a reboot. From this point, configuration (or re-configuration)
proceeds normally.
Use the Network Defaults Jumper to correct potential errors in a VertX controllers network configuration.
A jumper is supplied with the V1000, and is located across pins 6 & 8 of the Debug port for safe storage. Replace the
jumper across pins 6 & 8 for safe storage, after restoring network defaults.
1.
Remove the V1000 cover.
2.
Reboot the controller and place the supplied jumper over pins 3 & 5 of the Debug port while the Power LED is
green.
Note: The network reset opportunity occurs for 30 seconds while rebooting the controller.
3.
After 30 seconds, the Power LED flashes green five times, indicating success. When an error occurs, the LED
flashes red five times. In both instances, the LED turns off indicating a power cycle is required.
4.
Remove the jumper, return it to pins 6 & 8 of the Debug port and cycle power. The controller resets in
approximately 60-seconds. Once the reset is complete, the LED returns to green. After the 30-second window,
the LED returns to normal Red state. The controller is fully functional during this time.
CAUTION: During the controller rebooting process, all network configuration information is overwritten
and returned to the original defaults.
5.
Configure the controller for your installation parameters. See 3.1 VertX Communications, page 10.
6.
Replace the V1000 cover.