STEP 3: PROGRAMMING THE BOARDS
Using a MPLAB ICD3 programmer, the user must:
a) program the firmware to 001-000167-02 board (MPX board)
b) program the boot loader to 001-000166-02 board (Control Board). The firmware of the
Control Board will be programmed later through the webserver.
To upgrade the firmware:
a) Copy the folder upgrade_Mozart in the local disk C:\
b) Install ICD3 and MPLAB in your computer as indicated in the instruction manual of ICD3
c) Connect the ICD3 programmer to an USB port of your PC and to the Mozart transmitter
connectors (see the photos here below). Program first the 001-000167-02 board and after the
001-000166-02 board.
Fig. 5 – MPX Board programmer connector
d) Switch ON the Mozart (without output power)
e) Start MPLAB from your PC without inserting or modifying any value
f) Upload the firmware
g) Press any key to exit from the DOS window.
Fig. 6 – Control Board programmer connector
Mozart series calibrating procedure