Gait up GAIT UP GO Skrócona instrukcja obsługi - Strona 11
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Sprzęt medyczny Gait up GAIT UP GO. Gait up GAIT UP GO 12 stron. Medical device indicated for mobility and physical condition parameter assessment
What do you see/hear
The Gait Up GO mobile
application displays an error
pop-up after you select a test,
indicating
that
connect
to the Physilog6
sensor device
The Gait Up GO mobile
application displays an error
pop-up after you select a test,
indicating that the Physilog6
sensor device accessory has
incompatible firmware
The Gait Up GO mobile
application indicates an error
pop-up during a recording
The Physilog6 sensor device
accessory emits a bip sound
and briefly blinks orange
The
Physilog6
device accessory is blinking
yellow during the recording
When & how to perform a manual reset of the Physilog6 sensor device
In case the Physilog6 sensor cannot be connected to the Gait Up GO mobile application, after controlling
that the correct sensor is linked, that it has enough battery and is in proximity and after restarting the Gait
Up GO mobile application, a reset of the Physilog6 device can solve the problem.
•
Unplug Physilog6 if it is charging
•
Press the sensor button for 15 seconds, it will blink orange and beeps
•
Release the button and wait until the blinking stops
© 2020 Mindmaze SA & Gait Up SA. All Rights Reserved. MindMaze, Gait Up, Gait Up GO the Mindmaze LOGO, the Gait Up LOGO and Physilog are trademarks or registered
trademarks of Mindmaze Holding SA.
Troubleshooting
Problem
There is a problem with
the connection to the
Physilog6 sensor device
it
cannot
The
Physilog6
device has incompatible
firmware version
There is a problem
with
the
sensor device
The
Physilog6
device
performed a reset
sensor
The
battery
Physilog6 sensor device
accessory is getting low
What to do
Make sure that the sensor device
accessory is in proximity of your
mobile device.
Control that the sensor device
accessory has enough battery to
be connected to the ap- plication.
Click on the sensor information
button to check that the linked
sensor
corresponds to the sensor in your
possession (last four digits of serial
number on the back of the sensor
corresponding
indicated
application).
sensor
Update the sensor device firmware
by pressing the "Update Physilog"
button.
The
Physilog6
aknowledge the
inside the Gait Up GO mobile
application
recommendation
message.
sensor
Nothing needs to be done, the
accessory
has
sensor
solved its issue on its own.
of
the
Complete the test, then recharge
the Physilog6 sensor device
device
accessory
to
the
number
in
the
mobile
recording
is
interrupted,
error message
and
follow
in
the
error
device
accessory
the
just