Hidro-Water ATHENEA Podręcznik - Strona 11

Przeglądaj online lub pobierz pdf Podręcznik dla Systemy filtracji wody Hidro-Water ATHENEA. Hidro-Water ATHENEA 16 stron.

d. Lower the arm on the WATER STOP Antileak system and it's ready for use

7.- FAULTS, PROBABLE CAUSES AND POSSIBLE SOLUTIONS

SYMPTOM
1. Zero/low production
2. Plastic or synthetic taste.
3. Chlorine taste and smell
4. Unpleasant taste and
smell
5. White particles in the
water
PROBABLE CAUSE
a.
No water supply.
b.
Brass ball valve at entrance ful-
ly/partially closed.
c.
Cartridges obstructed.
d.
Membrane saturated.
e.
Antileak system activated.
a.
Worn Nanosilver Carbon cartridge.
a.
Worn cartridges.
a.
Contamination.
a.
Air in the system
b.
Excessive inlet pressure.
11
SOLUTION
a.
Wait until the water supply has been
restored.
b.
Open the inlet valve fully.
c.
Replace cartridges.
d.
Replace membrane.
e.
Check if the Antileak system has been
activated. If so, find the leak and fix it,
change the absorbent material and
lower the arm on the Antileak system.
a.
Replace cartridge.
a.
Change the cartridges.
a.
Change the filters, membrane, post fil-
ter and sanitise.
a.
Wait for the air to pass as there's no
urgent problem.
b.
Check the pressure regulator.
ref: MA-UF-0002-EN-V14.0-ATHENEA.pdf