Hidrotermal Hidro-ST80 Podręcznik użytkownika - Strona 11
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Żelazo Hidrotermal Hidro-ST80. Hidrotermal Hidro-ST80 12 stron.
6. How to build a steam bath room
Generally, steam rooms are built with glass steels or acrylic materials and building materials. Easy installation
and good insulation characterize both the glass steels and acrylic materials. However, they are sufficiently poor
heat resistant, especially easily break and get damaged, while the cost is high. They are only suitable for
temporary entertainment centers. For the steam room built with building materials, the only need is to take some
measures to keep insulated. They are not only low in cost with excellent heat resistance and long service life,
but also can be made according to your needs with no building space limits. In such case, a safe, comfortable
and low cost steam bath room with long service life will be a real thing for you. Steam bath room in most of
counties and regions are made in the way.
Chief Instruction
The following messages are aimed to help the person who install steam generator or build steam bath room
only. Subject to the complexity of the building and the climate varies etc., this chief instruction is a
recommendation only.
Aims
When you plan to build a steam room, keep comfort and leisure as an aim in your mind. A room with correct
designs and structures should be installed comfortable seats and in which the temperature can be reached to30-
40℃ in 15 to 20 minutes. If the space allows, it will be better to install seats with backrest or reclining benches,
these sorts of seats will make more comforts.
Considerations in Designing a Steam Room
1. Avoid using decay building materials because the steam room is highly humid and wet.
2. All surfaces in steam bathroom must be protected with water proof materials, e.g. tiles.
3. Both seats and ceiling should have a certain slope, 15cm for each meter. Such kind of design reduces the
space of the steam bathroom.
4. Easy cleaning and drainage must be taken into consideration when designing the floor drainage. For the
consideration of safety, the floor must be slipping proof.
5. The heights of steam bathroom must be limited to 2.4m or below. Heights over 2.4m will cause a high or
adequate temperature around the ceiling, while the temperature around the floor is low.
6. The place for installation of the steam generator should satisfy the following conditions:
a) Have enough space for sufficient operation and for being in the situation that the steam generator needs
maintenance or fails to function and needs spare parts replacements.
b) The steam generator must not be frozen or moistened, and the temperature must not exceed 40° C (Never
install the generator inside the steam bathroom or outdoors.)
c) The steam pipe from steam bathroom to generator should be less than 6m. The steam pipe shall slope to
the steam bathroom and be higher than the position of the steam head, so that condensation shall drain into the
steam room and will not gather in the tube. Furthermore, the steam pipe should be well insulated.
d) To install the steam head complying with the instructions. The owner shall not touch the steam head.
e) The water drainage channel must be unblocked when you are installing the steam generator.
7. When you decide to use a certain materials for the inner walls of your steam bathroom, please take a contact
with the manufacturer to make sure that this material is of heat resistant and anti-humidity type.
8. Steam bathroom must be completely closed.
9. Situating a window at the ceiling is not recommended. If do so, the materials must be of waterproof type and
the window shall be tightly closed when in use.
10. Window and natural lights are not recommended either. If do so, must be sure the height and
size of the window in the steam bathroom will not affect keeping a comfortable temperature in a
long period of time.