Auton PL-2-9 Instrukcja instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Systemy podnoszenia Auton PL-2-9. Auton PL-2-9 3 stron. Panel lift

Adjusting the limit switches
The Auton lift utilizes limit switches to control your preferred positioning of the unit.
The limit switches are located on the motor. Depending on the model you may have either a red or blue
limit switch motor head.
MOTOR
MOTOR
Using a power tool to adjust the limits will void the warranty.
The #1 screw controls the up travel.
The #2 screw controls the down travel.
Turn the #1 screw clockwise (-) to
the #2 screw clockwise (-) to decrease the down travel. Turn counterclockwise (+) to increase the down travel.
Before decreasing "up" or "down" travel, run the lift in opposite direction for approximately 6" and stop.
* If positioning requires more than 5 cycles of the lift, the built-in thermal overload protector will disable the motor to prevent
overheating and possible damage. The unit will automatically re-set itself within 10-15 minutes.
Red Motor Head (Model PL-3)
Limit switches are preset at factory
but may be changed.
Two (2) adjusting screws for the limit switches
are located at the right hand end of the motor
while facing the front of the unit.
Using a power tool to adjust the limits will void the warranty.
The #1 screw controls the down travel.
The #2 screw controls the up travel.
Turn the #1 screw clockwise (+) to increase the down travel. Turn counterclockwise (-) to decrease the down travel.
Turn the #2 screw clockwise (+) to increase the up travel. Turn counterclockwise (-) to decrease the up travel.
Before decreasing "up" or "down" travel, run the lift in opposite direction for approximately 6" and stop.
* If positioning requires more than 5 cycles of the lift, the built-in thermal overload protector will disable the motor to prevent
overheating and possible damage. The unit will automatically re-set itself within 10-15 minutes.
Installation support:
We take great pride in manufacturing the best lift systems in the world. Our design and production techniques enable simple installation.
n the event that you require assistance, do not hesitate to contact one of our technicians. We will be happy to answer your questions and resolve
any problems you encounter during the installation process.
Keep unit free of debris, keep covered prior to installation
#2 screw
(down travel)
de
crease the up travel. Turn counterclockwise (+) to increase the up travel. Turn
Phone Support: 661-257-9282, ext. 104 • Email Support: [email protected]
# 1 screw
(up travel)
Black
Limit switches are preset at factory
but may be changed.
-
+
Two (2) adjusting screws for the limit switches
+
-
are located at the right hand end of the motor
while facing the front of the unit.
# 2 screw
(DOWN travel)
MOTOR
MOTOR
Motor Head (Models PL-1 - PL-2)
# 1 screw
(down travel)
#2 screw
(up travel)
-
+
-
+