Aire 3828AR7314S Instrukcja instalacji - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Klimatyzator Aire 3828AR7314S. Aire 3828AR7314S 16 stron. Single split wall mounted air conditioner

INSTALLATION OF INDOOR, OUTDOOR UNIT

Read completely, then follow step by step.
Select the best location
Indoor unit
A
Do not have any heat or steam near the
unit.
Select a place where there are no
obstacles in front of the unit.
Make sure that condensation drainage
can be conveniently routed away.
Do not install near a doorway.
Ensure that the space around the left and
right of the unit is more than 5cm. The
unit should be installed as high on the
wall as possible, allowing a minimum of
5cm from ceiling.
Use a stud finder to locate studs to
prevent unnecessary damage to the wall.
More than 5cm
More than 2.3m
CAUTION
Install the indoor unit on the wall where the height
from the floors more than 2.3 meters.
Outdoor unit
B
If an awning is built over the unit to
prevent direct sunlight or rain exposure,
make sure that heat radiation from the
condenser is not restricted.
Ensure that the space around the back
and sides is more than 10cm. The front of
the unit should have more than 70cm of
space.
Do not place animals and plants in the
path of the warm air.
Take the air conditioner weight into
account and select a place where noise
and vibration are minimum.
Select a place so that the warm air and
noise from the air conditioner do not
disturb neighbors.
More than 10cm
More than 70cm
More than 5cm
More than 5cm
More than 60cm
More than 10cm
More
than 60cm
4
Rooftop Installations:
If the outdoor unit is installed on a roof structure, be
sure to level the unit. Ensure the roof structure and
anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
Piping length and elevation
Standard
Pipe Size
Capacity
Length
(Btu/h)
GAS LIQUID
(m)
18K(60Hz)
5/8" 1/4"
4 or 5
18K(50Hz)
1/2" 1/4"
4 or 5
24K(60Hz)
5/8" 1/4"
4 or 5
24K(50Hz)
5/8" 3/8"
4 or 5
A
Indoor unit
A
Oil trap
Indoor unit
In case more than 5m
CAUTION
• Capacity is based on standard length and maximum
allowance length is on the basis of reliability.
• Oil trap should be installed every 5~7 meters.
Max.
Max.
Additional
Elevation
length
Refrigerant
(m)
(m)
(g/m)
B
A
10
20
20
15
30
30
15
30
30
15
30
30
Outdoor unit
B
Outdoor unit
B