Aire SK Series Instrukcja instalacji - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Klimatyzator Aire SK Series. Aire SK Series 16 stron. Single split wall mounted air conditioner

How to fix installation plate
The wall you select should be strong and solid
enough to prevent vibration
Mount the installation plate on the wall with
A
four type A screws. If mounting the unit on a
concrete wall, use anchor bolts.
Mount the installation plate horizontally by
aligning the centerline using a level.
Type "A" screw
Thread
Weight
Measure the wall and mark the centerline. It
B
is also important to use caution concerning
the location of the installation plate-routing of
the wiring to power outlets is through the
walls typically. Drilling the hole through the
wall for piping connections must be done
safely.
Left rear piping
"D"
Hole center
Installation Plate
Marking-off line
Right rear piping
"C"
ø70mm
5
Drill a hole in the wall
Drill the piping hole with a ø70mm hole core
drill. Drill the piping hole at either the right or
the left with the hole slightly slanted to the
outdoor side.
WALL
Indoor
Outdoor