Autonics MP5W Series Instrukcja obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe Autonics MP5W Series. Autonics MP5W Series 8 stron. Multi pulse meters
Mode Setting
→
Parameter 0 group
[MODE]
RUN
→
Parameter group
[MODE] 2 sec
01) Press [▲], [▼] key or [MODE] key for 1.5 sec after entering parameter: select parameter groups.
Parameter Setting
• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• The parameter and setting value are cross-displayed on the display part.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [▼] key: Changes setting values.
■ Parameter 0 group
Parameter
Display
Default
HH
P0-1
comparative
PStHH 99999
value
H comparative
P0-2
value
PSt H 99999
L comparative
P0-3
value
PSt L 00000
LL comparative
P0-4
value
PStLL 00000
Max.
P0-5
monitoring
hPEK 99999
value
Min.
P0-6
monitoring
lPEK `9999
value
Comparative value output model
Parameter
Quintuple
HH comparative value
01)
○
H comparative value
○
L comparative value
○
LL comparative value
○
■ Parameter 1 group
Parameter
Display
Default
Input
P1-1
operation
F1 F1 to F16
MODE
mode
Input A
P1-2
IN-A NPnhF NPN.H.F : NPN non-contact input1
sensor type
Input B
P1-3
sensor type
IN-B NPnhF
P1-4
Output mode OUT-T STARD
Output
P1-5
hysteresis
HYS
0001
Delay
P1-6
monitoring
GUARD fDEFY
Start
P1-7
compensation
STArT
)0
timer
Input A auto-
P1-8
zero time
AUToA 999(9
Input B auto-
P1-9
zero time
AUToB 999(9
Memory
P1-10
OFF OFF, ON
retention
MEMO
01) In case of P1-1 Input operation mode F15, input B sensor type is not displayed and IN-B setting is same as IN-A.
02) [▲] key: Entering compensation time setting
[MODE]
[MODE] 3 sec
01)
Setting range
[Comparative value output model
]
01)
Operation mode
Setting range
F1, F2, F7, F9, F11,
0 to 99999
F12, F13, F16
0.01 to
F3, F4, F5, F6
time setting range
F8, F10, F14, F15
-19999 to 99999
• Varies according to P1-1 Input operation
mode and P2-2 Decimal point position of
display value
• Same parameters at parameter 2 group
are linked.
• Reset (PV): [◀] key for over 2 sec
Triple
-
○
○
-
Setting range
NPN.M.F : NPN non-contact input2
NPN.L.F : NPN contact input
PNP.H.F : PNP non-contact input1
PNP.M.F : PNP non-contact input2
PNP.L.F : PNP contact input
[Comparative value output model]
STARD : S (Standard)
OUT-H : H (High)
OUT-L : L (Low)
OUT-B : B (Block)
OUT-I : I (One-shot)
OUT-F : F (Deflection) *
[Comparative value output model]
0000 to 9999
• Varies according to P2-2 Decimal point
position of display value
[Comparative value output model]
F.DEFY: LL, L comparative output limit *
STAR.T: Start compensation timer
02)
[Comparative value output model]
0.0 to 99.9 sec
0.1 to 9999.9 sec
■ Parameter 2 group
Parameter
→
P2-1
Data bank
RUN
→
Decimal
point
P2-2
position of
display value
P2-3
Time unit
01)
Time range
P2-4
(unit: sec)
01)
Time range
P2-5
(unit: min)
01)
HH
P2-6
comparative
value
H comparative
Display
P2-7
value
condition
L comparative
P1-4 Output
P2-8
value
mode:
except F
LL comparative
P2-9
value
-
Input A
P2-10
prescale
mantissa (x)
-
Input A
P2-11
prescale
P1-4 Output
exponent (y)
mode:
except F
Input B
P2-12
prescale
P1-1 Input
mantissa (x)
operation
Input B
mode:
P2-13
prescale
except F13,
exponent (y)
F16
P2-14
Display cycle
Input B
P2-15
setting value
(INB)
01) To enter P2-4 time range (unit: sec) and P2-5 time range (unit: min) setting, press [▲] key at P2-3 time unit.
02) Only available operation mode F2, F16
■ Parameter 3 group
Display
condition
Parameter
-
Max. PV
-
P3-1
transmission
output value
P1-1 Input
operation
mode:
F2, F6 to 14,
F16
01)
Min. PV
P3-2
transmission
P1-1 Input
output value
operation
mode:
except F13
current
&
P3-3
output
* P1-1 Input
operation
Comm.
P3-4
mode:
address
except F16
Comm.
P3-5
P1-1 Input
speed
operation
Comm. parity
mode:
P3-6
bit
F1, F7 to 10
Comm. stop
P1-1 Input
P3-7
bit
operation
mode:
F1 to 12
*P1-4 Output
mode: S, B, F
Comm.
P3-8
response
P1-6 Delay
waiting time
monitoring:
STAR.T
P1-1 Input
operation
mode: F1, F4,
P3-9
Comm. write
F7 to 10
P1-1 Input
operation
mode:
P3-10
Lock
F7 to 10
P1-1 Input
operation
Parameter
P3-11
mode:
reset
F13 to 16
Display
Default
Setting range
[MP5W model]
1, 2
pBANK
1
DOT 00000 00000, 0000.0, 000.00, 00.000, 0.0000
tSEC T.SEC, T.MIN
tUNT
999.99: 999.99 s
9999.9: 9999.9 s
99.59.9: 99 m 59.9 s
tSEC 99(99
9.59.59: 9 h 59 m 59 s
99999: 99999 s
999.99: 999.99 m
9999.9: 9999.9 m
99.59.9: 99 h 59.9 m
tMIN 99(99
9.59.59: 999 h 59 m
99999: 99999 m
PStHH 99999
[Comparative value output model]
PSt H 99999
linked with parameter 0 group parameters
PSt L 00000
PStLL 00000
PScaH ^0000 0.0001 to 9.9999
10 01 10 - 9 (10
) to 10 09 (10
-9
PScaY
PScbH ^0000 0.0001 to 9.9999
10 01 10 - 9 (10
) to 10 09 (10
-9
PScbY
)05 OFF
or 0.05, 0.5, 1, 2, 4, 8 sec
02)
dISpT
COUnB 99999 1 to 99999
Display
Default
Setting range
[PV transmission (current) output model]
min. value to max. value (FS-H ≥ FS-L + 1)
Operation mode
Setting range
FS-H 99999
F1, F2, F7, F9, F11,
0 to 99999
F12, F13, F16
0.01 to
F3, F4, F5, F6
time setting range
F8, F10, F14, F15
-19999 to 99999
• Varies according to P1-1 Input operation
FS-L 00000
mode and P2-2 Decimal point position of
display value
[PV transmission (current) output model]
4-20, 0-20 mA
MA
4-20
[RS485 communication output model]
01 to 99
ADDR
01
[RS485 communication output model]
2400, 4800, 9600, 19200, 38400 bps
BPS
9600
[RS485 communication output model]
NONE, EVEN, ODD
PRTY
NONE
[RS485 communication output model]
1, 2
STP
2
[RS485 communication output model]
Comm. speed
Setting range
2400 bps
16 to 99 ms
4800 bps
8 to 99 ms
RSwT
20
9600, 19200,
5 to 99 ms
38400 bps
• Setting range varies according to P3-5
Comm. speed
[RS485 communication output model]
ENA: enable, DISA: disable
COmW
DISA
OFF : Unlock
LOC.0 : Lock All
LOC.1 : Lock parameter 1 / 2 / 3
LOC
OFF
LOC.2 : Lock parameter 2 / 3
LOC.3 : Lock parameter 3
ENA ENA: enable, DISA: disable
mRST
Display
condition
-
P1-1 Input
operation
mode:
F1 to 2,
F7 to 16
P1-1 Input
operation
mode:
F3 to 6
P1-4 Output
mode:
except F
-
-
P1-4 Output
mode:
except F
P1-1 Input
operation
mode:
F1 to 2,
F4,
)
9
F7 to 16
P1-1 Input
operation
mode:
F7 to 10
)
9
P1-1 Input
operation
mode:
F1 to 2,
F7 to 10, F16
P1-1 Input
operation
mode: F16
Display
condition
-
-
-
-
-
-
-
-
-
-
-