DynaQuip Controls WaterCop Instrukcja obsługi i instrukcja instalacji - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi i instrukcja instalacji dla Jednostka sterująca DynaQuip Controls WaterCop. DynaQuip Controls WaterCop 8 stron. Emergency leak detection and water shut-off system

Important!
Adherence to all local and municipal building, plumbing
and electrical codes as they pertain to the installation
®
of the WaterCop
System is of utmost importance.
Codes in some areas may require that a licensed
plumber be employed to do the installation, or that the
proper permits be obtained prior to any installation.
Even if local codes do not require a licensed plumber
to do the installation, it is necessary that the installer
has a professional level of competence in both
plumbing and electrical skills to perform the
installation. These instructions assume this level of
knowledge and skill. If in doubt, use a licensed
professional.
Pre-installation Testing of WaterCop
Although each unit is pre-tested at the factory, it is
highly recommended that the unit be tested prior to
installation to ensure proper operation in your home.
Operating the valve before connecting to the water line
will not damage it. But be careful!
• The valve closes with enough force to cut off a
finger.
• Be extremely careful to keep fingers and other
items out of the valve.
• Always use a grounded (3-prong) electrical outlet.
Manually Test the Valve
®
To test your WaterCop
system, gently pull the safety
plugs out from each end of the valve. Check the
position of the valve by looking in either threaded end.
In the open position, you will be able to see through the
valve; in the closed position only the shiny surface of
the ball will be visible. Place the base of the housing
on a sturdy surface, as close as feasibly possible to the
Installation Guide
®
location where it will be permanently installed. Plug the
WaterCop
power cord into a nearby grounded 115
®
VAC outlet. The valve position indicator lights should
now correspond to the actual position you noticed.
Green = Open. Red = Closed. Grasp both sides of the
housing (not the valve) with the valve pointing away
from you for safety. Being very careful not to have your
fingers or other objects near the valve openings, press
the colored circle just below the unlit indicator light. You
will hear the motor change the valve position. Again,
look into the threaded end of the valve to verify that the
valve has changed position. If it appears that the
valve has not turned from one position to the
other, DO NOT try to reposition the valve yourself
by inserting any tool or fingers into the valve.
Operate the valve several more times from open to
close, checking each time for proper positioning. If you
are experiencing trouble getting the valve to open and
shut, call the installation help line listed on the back
cover.
Manually Test the WaterHounds
Each WaterHound is a battery-operated radio
transmitter. The units are shipped without batteries.
Two fresh "AA" alkaline batteries are needed to power
each unit. To install batteries, remove the battery cover
retaining screws and cover located on the front of the
WaterHound, and install batteries in accordance with
the (+ and –) placement guide. Reinstall cover and
screws.
Follow suggestions found in the section titled
"Selection
of
WaterHound
recommendations where WaterHounds should be
placed. Locate a wall near the area you choose to
monitor. Avoid high traffic areas where cord or sensor
could be stepped on or kicked. Mount transmitter at a
convenient location on the wall, two to three feet above
the floor. This will help avoid damage to the
WaterHound and provide a strong signal. Use hook
and loop fastener included with the unit.
1. Following all safety precautions, make sure that the
WaterCop
is plugged in and the valve is in the
®
5
Locations"