activTek EAGLE 5000 Instrukcja obsługi - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Oczyszczacz powietrza activTek EAGLE 5000. activTek EAGLE 5000 16 stron. Electronic air purification system 100, 120, 220, and 240 volt systems
TROUBLESHOOTING
Indicators of Operation
Operation of the ion indicator lamp:
Turn the unit on and check that the small red/orange lamp is illuminated . The lamp is
located inside the unit and is viewed by looking into the unit through the front grill .
Illumination of the internal lamp verifies that the frequency type ionizer is functioning
properly . The lamp should stay illuminated as long as the unit is turned on .
Troubleshooting - What to look for first.
1. I have plugged in the unit, turned "ON"
the power switch and nothing happens...
what's wrong?
• Make sure the electrical outlet is capable
of providing power to the unit .
• Check the lint screen located at the back
of the machine to ensure that the safety
switch activator clip depresses the safety
switch .
• Check to see if the proper fuse is installed
and that it is serviceable .
• Ensure that the fuse cap is completely
seated and secured in its receptacle .
• Be sure the cord is fully plugged into unit .
2. The fan is operating although the unit
won't produce any ozone... what's
wrong?
• Check the purification plate(s) for
serviceability . If they are cracked
or broken, the plate(s) will require
replacement . Ensure maintenance
procedures required for the purification
plate(s) have been performed according
to the "Maintenance" section (page 11)
of this owner's manual . Order new plates
from your Ativtek Dealer .
• Electrical stainless steel contacts are not
contacting the screen portion of the
purification plate(s) . Inspect the unit for
any loose connections .
• Do not attempt to disassemble the unit,
due to the Limited Warranty of the
product .
3. How am I able to know if the Frequency-
Type Ionizer is working?
• Current models with the FT Ionizer system
have a neon light bulb mounted on the
base of the FT antenna . When the power
switch to the unit is turned ON, the neon
light bulb will illuminate, indicating that
the FT Ionizer is functioning normally
(see above, "Indicators of Operation") .
13