parts such as headlights.
7.
When for the first time using this
detector , please add 10-20 ml oil
and do not exceed this range.
8.
Change the test oil regularly. Pour
out any left oil in the detector before
refilling with new oil.
9.
Test oil: both liquid paraffin and
baby oil are OK. However, please
make sure there is no water in it
and no viscous liquids are allowed.
10. Equipped
with
protector. If the machine runs for a
long
period
automatically stop and provide
protection after overheating, at
which point the unit should be
turned
off,
stopped for 3-5 minutes.
11. You can use strong airflow outside
the device to cool the device, but do
not directly use liquid for heat
dissipation.
Please save this User Manual
Introduction
The SDT 205 is a professional tool for automotive
pipeline leak detection. Diagnostic Leak Detectors
can quickly locate hard-to-find leaks in any sealed
system using a visual smoke system, such as EVAP
systems, air intake systems, exhaust systems, air and
water leaks, pressurized air coolers, turbochargers,
pipes, fittings, hoses and many other components.
It helps technicians resolve issues quickly and at
once, reducing the cost of repeat vehicle returns,
dramatically
reducing
improving customer service.
Features
1. Small and portable, sized to fit in a toolbox.
2. Built-in air compressor, ready for diagnosis and
maintenance at any time.
3. Pressure display: leaks can be found by
maintaining a certain pressure value.
temperature
of
time,
it
will
disconnected
and
diagnostic
time
and
4. Compact, lightweight design
Specifications
Product Name: Smoke Leak Detector;
Input voltage:DC12V
Output pressure: ≤15Psi(≈1Kg)
Output smoke flow : 6(L/min)
Package size:360x320x240(mm)
Weight:4.2Kg
Structure
1-handle;2-Pressure gauge;3-oil
inlet;4-air switch;5-smoke
switch;6-Protection indicator;
7-
Power Indicator
9-Smoke outlet;10-Power socket;
Operation steps
● Open the Engine cover and hook the
detector to the front cover of the engine.
● Open the access port of the system to be
tested, and seal it with plugging the
standard tapered adapter. If the tested
system has multiple open accesses, please
block them with corresponding rubber
plugs.
● Connect to a standard tapered adaptor
with a tapered quick coupling on the smoke
exit pipe of the tested device.
●Connect the detector with a DC12V battery:
red clamp with positive terminal, black
clamp with negative terminal. Do not
connect in the opposite way.
● After the power supply is correctly
connected, the equipped air pump will start
to work and output smoke.
●If there is no leakage in the tested system,
the pressure gauge reading can reach more
than 15PSI. But if the reading is low and
fluctuates continuously, there is a leak.
;8-Oil outlet;