TROUBLESHOOTING
Problem
The evaporative air
cooler is not functioning
and does not respond
when buttons are
pressed.
No air flows from the
unit while the machine is
operating.
The pump functions but it
is not cool enough.
dcg16.it
Instruction manual
Possible Cause
Blackout or faulty power
Measure the input
connection.
voltage and connect to a
designated power supply.
AC fuse is damaged
Replace the fuse or
or the circuit stops
restart the unit.
functioning in order to
prevent power overload.
Remote control batteries
Change the batteries.
have run out.
Remote Control or
Repair or replace the
Control Panel is damaged
control panel with
another of the same
model.
Damaged motor
Repair or replace the
motor with another of the
same model.
Incorrect motor
Determine whether
connection or loose
or not the motor with
motor connection
connections are in order.
Thermal protection inside
Leave the unit off until
the motor is working
the fan motor is cool
enough to be used as
usual.
The dust filters clogged
Clean or replace the dust
or dirty clogged.
filters.
The cooling pads
Clean or replace the
clogged.
cooling pads.
The cooling pads are dry
Check the top water
or contain insufficient
distribution tray to
water while the
determine whether or not
evaporative air cooler is
there is a clog. Determine
working.
if the pump is functioning
correctly.
Excessively high relative
When the evaporative air
humidity.
cooler is used for a long
period of time the room
humidity will be very
high, so the evaporative
a cooler will be unable
to lower temperature as
much as when the room's
humidity is lower. Turn
the Cool mode of and
is lower. Turn the Cool
mode off and increase
ventilation.
Corrective Action
Recommended to use
Voltage meter to get the
right voltage.
If the problem remains
unsolved, please contact
Service Center
Contact Service Center
Contact Service Center
EN
Remarks