**If the service light comes on, count the number of flashes and see below
??
1 RED FLASH
The flow light will go out and the Service light will flash once
o Verify the that the filter is clean
? ? If filter is dirty, clean the filter to increase the overall flow.
o Verify the water exiting the filter is not being diverted away from the inlet of the manifold.
? ? Make sure they do not have valves closed off or water being diverted away to other
o Verify that the Manifold Strainer Screen is Clean
? ? The strainer screen is located in the bottom portion of the manifold on the inlet
? ? Even if the screen appears clean, run the pump for a few seconds to flush any
o The Tri Sensor may have Failed
? ? Check Tri Sensor Flow switch for continuity
o Tri Cable may have Failed
? ? Check Tri Sensor Cable for Continuity
??
2 RED FLASHES
o Cell may be Scaled
? ? If cell is dirty, put cell in bucket with 1 part muriatic acid to 4 parts water for 15-
? ? If cell scales within a week, unit may not be reversing polarity.
? ? If cell scales 2 weeks or longer, water is unbalanced.
o 20 amp fuse blown
o replace 20 amp fuse
o Verify that unit is grounded correctly
o On the PS at J3 location verify you have 12 to 12 ½ dc volts.
1/17/03
SOFT TOUCH TROUBLESHOOTING
= LOW FLOW OR NO FLOW
water features like waterfalls, therapy jets, etc. If they are diverting water away to
a water feature, they may have to adjust the valve so more flow goes through the tri
sensor to activate the flow. REMINDER: you need at least 15 GPM going through
the flow switch to activate it.
side.
debris that may have fallen back into the pipes.
?? See Diagram "4A"
?? Use a multi motion for continuity check
– Low Amps with Salt OK
minute intervals until scale is completely removed. HINT: VERIFY
CHEMISTRY TO DETERMINE WHY CELL SCALED.
? ? If you do not BAD POWER SUPPLY
2