Message
No Display / Blank Display
Lost communication between the power
‐ ‐ ‐ ‐
Alternating:
Output/24 hr. countdown
Lo SALt
Salt level is 2,300 ‐ 2,700 ppm (mg/L)
Add SALt
CLn CELL
CLn CELL SOOn
The voltage at the cell is 26 to 28 VDC.
High Voltage or Over Current has been
HIgH Curr Err
NO FLO
OPEn CELL Err
A temperature sensor error has been
SEnS Err
Low voltage or a short circuit has been
SHrt CELL Err
Black wire from PoolSync® to GND
Yellow wire from PoolSync® to A
Connect only one red
Green wire from PoolSync® to B
wire for PoolSync. If
Red wire from PoolSync® to VDC
using PoolSync on
additional devices,
leave red wire off on
those additional
devices.
DISPLAY MESSAGES & TROUBLESHOOTING
Problem
No Display
center and the generator cell
Alternating Display
Salt level is below 2,300 ppm (mg/L)
Cell may be scaled
detected and the system is locked.
Insufficient water flow
Cell blades are receiving no current
detected.
detected.
RS‐485 Data (+) ‐ Terminal A
RS‐485 Data (‐) ‐ Terminal B
RS‐485 Data (+) ‐ Terminal A
RS‐485 Data (‐) ‐ Terminal B
Pool cover Switch
(dry contacts)
1. No power to the Power Center, check breaker. If unit is wired to a time
clock, make sure it is turned on.
2. Transformer wiring is incorrect, check it is wired properly for incoming
voltage.
3. Fuse (10A) may have failed, test and replace if necessary.
4. Transformer or Power Center circuit board has failed, replace the Power
Center. (p/n: ECP0312)
Check the cell cord connection at the power center for damage to the wire.
Normal operation, unit is in BOOST mode. Press and hold both the Up
Arrow and Down Arrow simutaneously to activate/deactivate BOOST
MODE.
Add Salt to achieve 3,500 ppm (mg/L).
Add Salt to achieve 3,500 ppm (mg/L).
High volts are going to the cell. Check cell for scale, clean as necessary and
balance water.
Chlorine is still being generated. The cell may be dirty or have calcium
build up. Inspect and clean the cell as needed.
Possible undissolved salt brushed into the main drain. The salt will need to
dissolve for this condition to normalize. The system will automatically
recheck in one hour increments to see if this condition persists. If the
condition persists, the system will lock with a high current error fault. A
power reset will be required to clear this fault.
1. Check pump for proper operation and service as necessary.
2. Check filter: clean/service as necessary.
3. Check system valve settings for proper flow to the unit.
4. Check for obstruction in the cell (debris or scaling accumulation).
5. Flow sensor may need to be serviced or replaced. Contact a local Service
Center for assistance.
Check for loose or damaged wiring, inspect cell for damage.
Contact a local Service Center for assistance.
Chlorine generation is halted. If the voltage remains low, the system will
automatically re‐test for 1 hour. If the issue persists, contact a local Service
Center for assistance.
Solution
LTM1034