3
Battery low
4
Time limits
exceeded
5
Unsuccessful
start
6
Operation
cycle too
short
8
CAN-bus
error
9
Settings error Settings have been
11
Heater no
connection
14
The module has
determined that battery
voltage at heater
startup or during heater
operation is lower than
specified in the settings
4.1 or 4.2
Time limit for
autonomous operation
of the heater is
achieved (with active
setting 2.1)
The heater was
switched off
spontaneously at
startup
The heater was
switched off
spontaneously with
operating time less
than 20 minutes
There is a problem
with connection of the
module to the CAN-
bus
incorrectly stored in
RCP memory
The heater is
unplugged from CAN-
bus or is out of order
Charge car's battery with
special charger (or start engine
to charge) or cancel 4.1/4.2
module's settings
Run the engine or cancel 2.1
module's setting
Make diagnostics of the heater
if the error occurs again
Make diagnostics of the heater
if the error occurs again
Check the connection
Reset the settings (8.1.1),
readjust RCP
Make diagnostics of the heater