INSTRUCTIONS: REPLACEMENT/SAFETY GEAR; Code: DYN 32.03.00
Date: 29/06/2016
Revision: 00
3. Unscrew the DIN 912 M6 screws from the shoe according to Figure7.
4. Replace the shoe for one of the appropriate thickness.
5. Replace the screws, according to the assembled shoe thickness.
6.
⚠
For these safety gear models, adapting the shoe thickness to the guide rail centre is done via
the block. If the shoe replacement is not the same type, they will not fit together. The hole
measurements to the guide rail centres that appear in the usage and maintenance instructions
will not be valid for this replacement. These measurements may vary by several millimetres,
depending on the shoes.
Figure6 Safety gear PR-2500 UD V50/ PQ-3400 UD
Shoe thickness
M6x25 DIN 912 8.8
7-8-9-10-11
M6x22 DIN 912 8.8
12-13-14
M6x20 DIN 912 8.8
15-15,88-16
Screw type
8