SAFETY PRACTICES & PRECAUTIONS
This Euro Hood system is designed
to remove smoke, cooking
vapors and odors from the cooktop
area.
WARNING:
ALL WALL AND FLOOR OPENINGS WHERE THE Euro Hood IS iNSTALLED MUST
BE SEALED.
ConsuHt the cooktop
or range instaHHation instructions
given by the manufacturer
before making any
cutouts.
MOBHLE HOME HNSTALLATHON-The instaHHation of this Euro Hood
must conform
to the
Manufactured
Home Construction
and Safety Standards, TitHe 24 CFB, Part 3280 (formerHy FederaH
Standard for Mobile Home Construction
and Safety, TitHe 24, HUD, Part 280). Three wire power suppHy
must be used and the appHhnce wiring
must be revised. See EHectricaHRequirements
(page 5).
[] Venting system MUST terminate
outside the home.
[] DO NOT terminate
the ductwork
in an attic or other encHosed space.
[] DO NOT use 4" Haundry-type waHH caps.
[] FHexibHe-type ductwork
is not recommended.
[] DO NOT obstruct
the flow of combustion
and ventiHation air.
[] FaiHure to foHHowventing
requirements
may resuHt in a fire.
[] EHectricaHground is required on this Euro Hood.
[] HfcoHd water pipe is interrupted
by pHastic, non-metaHHic gaskets or other materiaHs, DO NOT us
for grounding,
[] DO NOT ground
to a gas pipe.
[] DO NOT have a fuse in the neutraH or grounding
circuit.
A fuse in the neutraH or grounding
circuitcouHd resuHt in eHectricaHshock.
[] Check with a quaHified eHectdcian if you are in doubt as to whether
the Euro Hood is properHy
grounded.
[] FaiHure to foHHoweHectricaHrequirements
may resuHt in a fire.
WARNING:
TO REDUCE THE RiSK OF FIRE, ELECTRICAL SHOCK, OR iNJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Use this unit only in the manner intended
by the manufacturer.
Hfyou have any questions, contact the
manufacturer.
Before servicing or cHeaning unit, switch power offat service pane[ and Hockthe service
disconnecting
means to prevent
power from being
switched
on accidentaHHy. When the service
disconnecting
means cannot be [ocked, secureHy fasten a prominent
warning
device, such as a tag, to
the service panel
HnstaHHationWork And EHectdca[ Wiring
Must Be Done By QuaHified Person(s) Hn
Accordance
With AM[AppHicabHe Codes And Standards, HncHuding Fire-Rated Construction.
Sufficient
air is needed for proper
combustion
and exhausting
of gases through
the flue (chimney)
of fue[
burning equipment
to prevent backdrafting.
FoHHow the heating equipment
manufacturer's
guideHine
and safety standards such as those pubHished by the Nationa[ Fire Protection
Association
(NFPA),and
the American
Society for Heating, Refrigeration
and Air Conditioning
Engineers (ASHRAE), and the
[oca[ code authorities.
When cutting
or driHHing into wall[ or ceiHing, do not damage
eHectrica[ wiring
and other hidden utiHities.
NOTE: Ducted fens must elweys be vented to the outdoors.