Agrowtek MX1i Instrukcja obsługi - Strona 7

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kontroler Agrowtek MX1i. Agrowtek MX1i 12 stron. Intelligent reversing motor controller

Agrowtek MX1i Instrukcja obsługi

AC Motor Wiring

AC power (120V) must be supplied to the relay by a branch protected circuit (circuit breaker) panel. Power
to the motor is switched by the relay to the output terminals. Limit switches on the motor are wired at the
motor. Conduit is recommended for wiring connections.
CIRCUIT BREAKER
AC motors must be wired to include the limit switches in the motor to terminate operation and prevent
damage to a structure in the event the controls have a failure.
7
LINE
NEU
GND
+24Vdc
GND
FROM
FROM
MX1i-AC
GND
LIMIT SWITCHES
L1
T1
NEU
T3
L2
T5
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
L1
L2
NEU
GND
GEAR MOTOR
(RIDDER RW-45)
A/C TERMINALS
MOTOR GROUND (PE)
T2
MOTOR FORWARD (W1)
T4
MOTOR NEUTRAL (U1)
T6
MOTOR REVERSE (V1)
TO
MOTOR