Agrowtek MX3i Instrukcja obsługi - Strona 6
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Kontroler Agrowtek MX3i. Agrowtek MX3i 13 stron. Intelligent reversing motor controller
Internal Component Locations
1
3
4
1. Power Input
2. Motor Outputs
3. Motor Fuse
4. DC Power
DC Power Connections
12 - 24Vdc is required to operate the relay 's processor and contacts which may be supplied via:
a) the GrowNET™ RJ-45 port from a GCX control system or HX8 hub,
b) the 2.1mm DC barrel jack and included power supply, or
c) the Vin terminal block on the circuit board for DIN rail power supplies.
6
3
L1
L2
L3
REPLACE FUSE
MAX 10A
Input connections for motor power.
Output connections for motor.
Fuse sized according to specifi cations. Replace only with recommended fuse.
Optional DC power connection for backup power.
DC Power In
Terminal Block
© Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
A
B
C
GND
DC Barrel Jack
2
RJ45
GrowNET Port