CORA CVR1 Instrukcja instalacji

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Stojaki i stojaki CORA CVR1. CORA CVR1 2 stron.

CVR1
1. FIXING the FIRST RACK
a) Use included 8mm x 40mm pin head torx screws and 10mm x 40mm nylon sleeves
b) Locate suitable area for rack installation with correct clearance on all sides.
c) Draw a horizontal line to mark height of lower fixings: 1000mm above surface
d) Place rack in desired position and mark all fixing points with a suitable marker.
e) Drill holes using a 10mm masonry drill bit to a depth of 40mm. For best results use
a 6mm bit first to prevent wandering of the larger bit. Clear holes of dust.
Do not drill over plumbing and/or electrical conduits.
f) Tap nylon sleeves into holes. Place rack in position and partially tighten screws
starting from the top position. Once all nuts are on, continue to tighten until firm.
3.
FIXING MULTIPLE RACKS : AS2890.3 (2015) compliant spacing
CVR1 & CVR3 option: Staggered Heights
If adjacent racks are staggered at alternating heights of 300mm, they can be positioned a
minimum of 500mm centre to centre, or to any obstruction. As the first rack has the
lower fixings mounted 1000mm above surface level, the next rack would be mounted
with lower fixings at 1300mm above surface level. The following rack back at 1000mm.
*If AS2890.3 (2015) compliance is not required, reduced spacings of 400-450mm may be
considered. Reduced spacing is less user friendly.
CVR1 & CVR3 option: Same Heights
If adjacent racks are all mounted at the same height, they must be positioned a minimum
of 700mm centre to centre, and 500mm to any obstruction.
CVR2: Same Height Only
Adjacent racks must be positioned a minimum of 1000mm centre to centre, and 500mm
to any obstruction.
*If AS2890.3 (2015) compliance is not required, reduced spacings of 650-900mm may be
considered. Reduced spacing is less user friendly.
PHONE 1800-249-878 • FAX 1800-249-879 • [email protected]
INSTALLATION GUIDE
CORA CVR SERIES
CVR2