Galvin Engineering Ezy-Drink TD25XEB Podręcznik - Strona 3
Przeglądaj online lub pobierz pdf Podręcznik dla Produkt hydrauliczny Galvin Engineering Ezy-Drink TD25XEB. Galvin Engineering Ezy-Drink TD25XEB 5 stron.
INSTALLATION
IMPORTANT: Galvin Engineering products must be installed in accordance with these installation instructions
and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical
supply conditions must also comply to the applicable national and/or state standards. Failing to comply with
these provisions shall void the product warranty and may affect the performance of the product.
1. Fit Body & Mouthguard Outlet
−
Remove the lock nut.
−
Fit the body into the trough ensuring the
rubber o-ring is placed between the
trough and the body.
−
Secure outlet underneath with the
supplied back nut and tighten the screws
using a 2.5mm hex key
−
Take care not to over-tighten.
3. Fit the Piezo Button
−
Fit the piezo button and coloured washer
into the pre-drilled hole.
NOTE: Ensure the o-ring is between the
button and the coloured washer.
−
Secure using the supplied nut.
Version 2, 23
Solenoid
Coil
2. Fit Solenoid and Outlet
−
Fix the solenoid in position ensuring that the
solenoid coil is not facing downwards.
−
Fit the flexi hose to solenoid outlet and bubbler.
−
Connect water supply to solenoid inlet.
4. Connect the Piezo Button to the Controller
−
Connect the controller to the solenoid, piezo button
and battery pack.
rd
March 2021, Page 3 of 5