Galvin Engineering Ezy-Wash TF81HJS Instrukcja instalacji produktu - Strona 4

Przeglądaj online lub pobierz pdf Instrukcja instalacji produktu dla Produkt hydrauliczny Galvin Engineering Ezy-Wash TF81HJS. Galvin Engineering Ezy-Wash TF81HJS 5 stron. Pre-rinse tapware

Galvin Engineering Ezy-Wash TF81HJS Instrukcja instalacji produktu
Version 1, 3 August 2017, Page 4 of 5
TF81HJS
5. Fit pre-rinse riser assembly
1. Fit compression nut to support rod, followed
by the compression cone and locate the
support rod into wall bracket.
2. Fit the pre-rinse riser assembly through the
drilled hole on the bench.
7. Secure support rod
1. Fasten support rod securely against riser.
2. Tighten compression nut on wall bracket to
secure the support rod. The rod is now rigid.
TF81HJP
6. Secure pre-rinse assembly
8. Test unit
Version 2, 3 August 2017, Page 4 of 5
TF80H-S
Secure pre-rinse assembly with the supplied
flanged back nut; ensure the sealing rubber
washer is placed underneath the pre-rinse
body flange.
TF81HJS
Once all fittings have been tightened
securely, connect the unit to the mains
water.
Turn on water and test the unit for any
leaks.
TF80HJP
TF81HJP