6. Water fl ow outlet connection
➀ Connect the tubing
between the water fl ow
outlet and the hose barb
inlet.
It is recommended that a
prefi lter be used with the
Turbo-Twist to limit the
amount of debris entering
the sterilizer.
Warning:
Never install a
valve directly
on the tubing
between the
main body and
the aquarium.
Note: Make sure that the tubing is not carrying the weight
of the Turbo-Twist UV Sterilizer. Use the Turbo-Twist brackets
to support the unit.
7. Start water fl ow
Turn on water supply to the Turbo-Twist. Once proper water fl ow has been established, tilt the unit and let
the air bubbles inside the tubing and the main body escape. Examine the unit and check for any leaks.
8. Power up Turbo-Twist
Connect the Turbo-Twist to the power supply. Verify that the UVC
lamp is working properly, indicated by the light blue glow emitted
through the lamp-on indicator. The light from the lamp-on
indicator will not affect the skin or the eye.
C A U T I O N
• Never look directly at the unshielded lamp as ultraviolet
radiation is harmful.
• Disconnect the UV Sterilizer from the power supply when
installing or performing maintenance.
• Never submerse the UV Sterilizer in water.
5
WATER FLOW OUTLET
CANISTER
FILTER
HOSE BARB
INLET
WATER FLOW
HOSE BARB INLET
WATER FLOW
LAMP-ON
INDICATOR
Maintenance
Maintenance
To ensure superior performance, the quartz sleeve
should be cleaned periodically.

Cleaning the quartz sleeve

➀ Disconnect UV Sterilizer from
outlet, turn off the pump and let
water drain from Turbo-Twist.
➁ Lift the red safelock and unlock
the quartz housing. (Picture 1)
➂ Carefully twist the quartz housing
and the main body opposite of
each other. (Picture 2)
➃ Slide the quartz sleeve out of the
main body. (Picture 3)
➄ Wipe the quartz sleeve using a soft,
damp cloth. Do not use household
cleaners or abrasive scrubbers to
clean the quartz housing.
C A U T I O N
• Never look directly at the unshielded lamp as ultraviolet
radiation is harmful.
• Disconnect the UV Sterilizer from the power supply when
installing or performing maintenance.
• Never submerse the UV Sterilizer in water.
SAFELOCK
(PICTURE 1)
QUARTZ HOUSING
(PICTURE 2)
MAIN BODY
SAFELOCK
(PICTURE 3)
QUARTZ SLEEVE
➅ Once clean, reinstall the quartz sleeve
into the main body and push the red
safelock into the lock position.
6