Coram Showers OPTIMA Podręcznik - Strona 13
Przeglądaj online lub pobierz pdf Podręcznik dla Armatura łazienkowa Coram Showers OPTIMA. Coram Showers OPTIMA 16 stron. Extender pack
Również dla Coram Showers OPTIMA: Podręcznik (2 strony), Podręcznik (2 strony)
10
PN40260
PN4745
Fit 'flipper seals' (PN40260) onto the edge of the fixed
panels. Ensure the flipper seal 'flaps' are on the
inside.
Note: Wetting the glass with water will help fit the seals.
From inside the enclosure, tighten all 4 fixed panel
bracket grub screws onto the glass using the allen
key - do not overtighten. Fit the cover caps (PN4745)
into the holes.
12
IMPORTANT: It is advised that this stage is carried out by two people to avoid damaging the runners, rails or doors.
From inside the enclosure, push fit the 'runners' fitted to the top and bottom of the doors, onto the 'door rollers' pre-fitted in the
top and bottom rails.
11
Inside
PN
40259
Push fit 'flipper seals' (PN40259) onto the back edge of the doors.
Ensure the flipper seal 'flaps' are on the outside of the doors.
Push fit 'magnetic seals' (PN80564) onto the closing edge of the
doors (the same side as door handle hole).
Note: Ensure the magnetic seals are positioned as shown.
Note: Wetting the glass with water will help fit the seals.
From inside
PN80564
Outside
face of
door
PN80564
Door
handle
hole
Top of doors
Bottom of doors
PN40259
PN80564
Outside
face of
door
Door
handle
hole
13