Prior to this, verify that there is no power at any of the motor terminals.
1. Disconnect or turn off the circuit breaker to remove power (if a hand or drum switch is connected to the motor it will
need to be disconnected). Takes notes before disconnecting the switch in the unlikely event it will need to be reconnected.
2. See motor connections using the tables on pages 4 and 5 for terminal connections specific to the motor.
3. 120VAC power is connected to the line and neutral terminal of the receiver.
NOTE: After completing the installation, if the motor goes the wrong direction, simply swap the wires connected to T5 and
T8 on the receiver. The motor will now rotate in the correct direction. The 120VAC light connects between "common" and
"light" terminals on the receiver.

Wiring Instructions

T8
T5
LIGHT
T2, T4
T1, T3
AC IN NEUT
AC IN LINE
LRF120VPR1L
Instruction Manual
Page 3 REV B 05/20/19