FILTER MAINTENANCE
Do not use any cleaning oil with volatile or harsh substance and metal brush while cleaning
the air filter as it will damage the surface of the air filter.
When performing cleaning work, please switch off all power supplies to avoid electric shock.
Always wear protective hand gears when performing cleaning to avoid personal injuries.
Always beware of objects below the feet and falling dirty particles when performing cleaning
at a high position from ground.
Do not use heating equipment to dry up the unit after cleaning as it will deform the unit's
shape and damage its function.
MAINTENANCE OF THE HIGH EFFICIENCY COMBO FILTER
The "Filter Change Indicator" will indicate the need for the
change of air filter. Irregular service and maintenance of
the air filter will reduce the functionability of the air filter,
or lead to malfunction or even damage.
Set the frequency of the air filter maintenance according
to the usage capacity within the given environment. We
recommend a regular cleaning every 30 days, and a
replacement of the air filter every 180 days. If the usage
is heavy, the cleaning and replacement period can be
adjusted accordingly.
About the Air Filter Lifespan
Metal Filter
High Efficiency Combo Filter
Activated Carbon Filter
1. The need for change of the High Efficiency Combo Filter of every unit may differ depending on the kind of
environment and the usage capacity. Please replace the filter when necessary.
2. Set the frequency of the air filter replacement according to the usage capacity and environment settings.
3. The air flow and air capture efficiency may deteriorate due to the kind of environment usage and over time.
If the High Efficiency Combo Filter arrow indicator become blacken entirely, please change and replace the
filter immediately.
4. In the event of environment with reasonably good conditions, where air particles with the diameter of less
than 2.5um and condensity of less than 50ug/m
major statistical discrepancy of the test reading, which may cause the above efficiency performance to
decrease. (The manufacturer uses TSI8530 as the standard measuring equipment)
Cleaning & Replacing the Air FIlter
Please follow the below steps accordingly when
cleaning the air filter.
1. Shut down all power supply
2. Loosen the Inspection Door.
WARNINGS
CLEANING
Once every 30 days
Once every 30 days
Once every 30 days
3
, the accuracy of the sensory components may lead to a
Filter Change
Indicator
REPLACEMENT
Not needed
As and when required by the Filter Change Indicator
As and when required by the Filter Change Indicator
Filter
Change
Temperature
Wind
Modes
Speed
PLUS
DIRECT
SMART
BYPASS
HIGH
MID
LOW
SLEEP
page 8