Corbin Russwin CL33600 Instrukcja instalacji - Strona 16
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Zamki Corbin Russwin CL33600. Corbin Russwin CL33600 16 stron. Access 600 tcrne1 series cylindrical lockset
Before closing door test for cylinder function of lock cylinder
and Inside lever:
a. Insert key into cylinder and rotate.
b. The key will retract the latch. Key should rotate freely.
c. Inside lever retracts latch.
d. Close door, ensure latch fully extends into strike
and does not bind.
Note: Once electrical wiring has been successfully
completed according to proper application, follow
the following step:
a. Turn power ON.
b. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
c. Present proximity credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., when prox
credential is presented to reader that the door unlocks.
7) Mechanical Operational Check
8) Electrical Operational Check
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.