This docking station has a built-in power supply and is designed to be used with an 11 - 28
volt DC system. The voltage output is factory set at 19 volts and current limited to 4.5
amps. Power is provided using the wires located on the back side of the docking station.
IMPORTANT: Make sure that you have read this entire section before you begin wiring!
1. Install docking station into vehicle, making sure that all bolts are tight.
2. Attach the BLACK ground wire to the location where the vehicle battery grounds to
vehicle chassis.
3. Attach the RED wire to the supply voltage (V+) from the vehicle.
IMPORTANT REMINDERS:
Use only SAE J1128 Type GPT number 14 AWG stranded wire (minimum) to attach the
docking station to the vehicle's electrical system.
Connect lead wires to the disconnect pigtail using the butt splice connectors provided with the
docking station. Caution: The butt splice connections must be made as close
to the docking station as possible using the disconnect pigtail provided with the docking
station. The disconnect must be easily accesible. When assembling the butt splice connectors
use only Panduit crimp tools CT-100, CT-600, CT-1525, CT-1550 OR CT-1551.
Route the lead wires to the battery. Total wire in the circuit must not exceed 30 feet and
must conform to SAE standard J1128.
Protect the lead wires from abrasion and chafing by using wire loom or conduit, and route
away from moving parts or areas where high temperatures may occur.
Connection of the supply voltage (V+) must be kept as close to the battery as possible.
The power connection must be made with the 10 amp in-line fuse and fuse holder provided
with the dock. Connect the fuse holder to the lead wire using the butt splice connectors
provided with fuse holder. When assembling the butt splice connectors use only Panduit
crimp tools CT-100, CT-600, CT-1525 or CT-1551.
The fuse holder location must be kept within 10 inches of the connection to the
battery positive, away from moving parts, and temperatures that exceed 180 degrees F.
Caution: If the fuse holder requires replacement it should be replaced by qualified service
personnel using Littlefuse part number FHM1 (Gamber-Johnson part number 11689). This
device conforms to ASTM standard D471 and SAE standard J1128.
Fuse must be inserted in supplied fuse holder. Caution: For continued protection against risk
of fire replace only with the same type and rating of supplied fuse. The provided fuse is UL
Listed, rated at 10 amp, 32 volt AC/DC fast acting.
If a timing device is used follow the instructions of the manufacturer of that device. It must
be wired in-line with the supply voltage (V+) to the docking station.
If you have any installation questions, please call Gamber-Johnson customer support at
1-800-456-6868
POWER SUPPLY INFORMATION
WIRING INSTRUCTIONS
Refer to Figure 2
Page 3 of 6