Adeunis RF ARF8170BA-B04 Skrócona instrukcja obsługi - Strona 9

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Przyrządy pomiarowe Adeunis RF ARF8170BA-B04. Adeunis RF ARF8170BA-B04 10 stron. Dry contacts transceiver combined with a water-leak sensor

Adeunis RF ARF8170BA-B04 Skrócona instrukcja obsługi
WATERLEAK SPOT - Package IoT - Quick start guide 1.0.0
WATERLEAK SPOT - Guide utilisateur / User guide version V1.0.0
WATERLEAK SPOT - Guide utilisateur / User guide version V1.0.0

1.2.2 The DRY CONTACTS transceiver

There are two key rules to optimize radio ranges.
The first one consists of positioning your product as high as possible.
The second one consists of limiting the number of obstacles in order to avoid excessive attenuation of the radio wave.
Position: Insofar as possible, install the transmitter at a minimum height of 1.50 m and do not attach it to the wall.
Obstacles: Ideally, the product must be 20 cm away from any obstacle and, if possible, near an opening (the closer the obstacle is, the more
the emitted power will be absorbed). All the materials encountered by a radio wave will attenuate it. Bear in mind that metal (metal cabinets,
beams, etc.) and concrete (reinforced concrete, partitions, walls, etc.) are the most critical materials for the propagation of radio waves.
20 cm
Optimized positioning

1.3. Starting up the product using a magnet

Once the product has been configured and its assembly has been final-
ized, the product is ready to be started up.
The start-up is carried out using a magnet which you place on the
upper part of the product (cf. the diagram below). The magnet must be
held in position for at least 6 seconds so as to confirm the start-up of
the product. When the magnet is well detected, the green LED lights up
for 1 second (LED light visible under the product).
Once the DRY CONTACTS validates its start-up, it immediately trans-
mits status frames followed by a data frame (according the defined
periodicity).
The product offers 3 fastening methods that enable numer-
ous ways of positioning it depending on the environment
where it has to be deployed :
- Tube or mast fastenings
- Fixing with screws
- DIN-Rail fixing
Refer to "INSTALLATION AND USE" paragraph of the DRY
CONTACTS User Guide available online :
https://www.adeunis.com/en/produit/dry-contacts-2/
Low radio range
Position of the magnet
to start the product
9 of 10
FR
EN