Adexa 6G-TRH60 Instrukcja instalacji i obsługi - Strona 13
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla grill Adexa 6G-TRH60. Adexa 6G-TRH60 20 stron. Gas lava rock grill
Operation
Lighting Main Burners
The LAVA ROCK GRILL are fitted with Flame Failure Protection is incorporated for each burner by
way of a thermo-electric system which will shut off the gas supply to that burner in the event that
the burner goes out, so that un-burnt gas is not expelled.
Before using electronic pulse ignition, open the bottom and put a No.7 battery in it
Turn the knob to align" ●" with salient position. The valve is OFF.
⚫
⚫ Hold down the valve knob and at the same time press down igniter.
Keep pressing the knob about 5-10 seconds, and observe stability of fire. After ignition, release
⚫
the knob 20s later.
The burner should stay alight - if not, close the burner, wait for 5mintues, then repeat above
⚫
ignition procedure.
To work in MAX power, turn gas control knob to 'HIGH'
⚫
To work in MIN power, turn gas control knob to
⚫
To achieve simmer control, turn gas control knob between the 'HIGH' and 'LOW' positions to
⚫
achieve the temperature required.
⚫
To turn "OFF" the appliance completely, turn the gas control knob completely clockwise to
the "●" position, the burner will extinguish.
Tip: There is air in the pipeline when the first time light the fire, then can normally light the pilot light until
flow out air.
Turning OFF Main Burners
Rotate the gas control knob to the 'OFF position. The main burner will extinguish.
Main burner air supply
1. For efficient burner operation, a proper balance of gas volume and primary air supply must be
maintained which will result in complete combustion. Insufficient air supply results in a yellow
streaming flame. Primary air supply is controlled by an air shutter on the front of the burner.
2. Loosen the screws on the front of the burner and adjust the air shutter to just eliminate the
yellow tips of the burner flame. Lock the air shutter in place by tightening the screws.
CAUTION
The space between the legs at the bottom admits combustion air. DO NOT BLOCK THIS SPACE.
All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all
that is required to put the unit in service.
Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the
units' sides or back. Avoid wall type fans which create air cross-currents within a room.
It is also necessary that sufficient air should be allowed to enter the room to compensate for the
amount of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure
will occur, affecting operation and causing undesirable working conditions.
A properly designed and installed hood will act as the heart of the ventilating system for the room
or area in which the unit is installed, and will leave the unit independent of changing draft
.
11