Gree GDN100AM-A3EBA1A Instrukcja obsługi - Strona 16
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Osuszacz powietrza Gree GDN100AM-A3EBA1A. Gree GDN100AM-A3EBA1A 19 stron.
14
● Unit's Malfunction Codes
Display
Malfunc on
Code
Name
F1
Malfunction of
indoor ambient
temperature
sensor
F2
Malfunction of
indoor evaporator
temperature
sensor
F5
Malfunction of
discharge
temperature
sensor
L1
Malfunction of
humidity sensor
C5
Malfunction of
jumper cap
E5
Overcurrent
protection
F0
Freon-lacking
protection
Possible Causes
1. Connection terminal between
sensor and controller is
loosened or poorly contacted;
2. Thereʼs short circuit due to
trip-over of the parts on
controller;
3. Sensor is damaged (Please
check it by referring to the
resistance table for
temperature sensor);
4. Control board is broken.
1. The wiring terminal between
indoor evaporator temperature
sensor and controller is
loosened or poorly contacted;
2. Thereʼs short circuit due to the
trip-over of the parts on
controller;
3. Indoor evaporator tempera-
ture sensor is damaged
(Please check it by referring to
the resistance table for tempe
rature sensor);
4. Control board is broken.
1. The wiring terminal between
outdoor discharge tempera-
ture sensor and controller
is loosened or poorly contacted;
2. Thereʼs short circuit due to the
trip-over of the parts on
controller;
3. Outdoor discharge tempera-
ture sensor is damaged
(Please check it by referring to
the resistance table for tempe
rature sensor);
4. Control board is broken.
1. Thereʼs short circuit due to the
trip-over of the parts on
controller;
2. Sensor is damaged (Please
check it by referring to the
resistance table for tempera-
ture sensor);
3. Controller is damaged
1. No jumper cap on controller;
2. Jumper cap hasn't been
installed or inserted correctly;
3. Jumper cap is damaged;
4. Controller is damaged.
1. Relay is short-circuited or
broken-circuited;
2. The unit operates in extreme
conditiions with very high tem-
perature and humidity level.
1. Refrigerant is leaking
2. System is blocked
Solu on
1. Re-energize the unit after
turning it off and pulling out
the plug for 30min;
2. If there's still malfunction,
please contact after-sales
service.
1. Re-energize the unit after
turning it off and pulling out
the plug for 30min;
2. If there's still malfunction,
please contact after-sales
service.
1. Re-energize the unit after
turning it off and pulling out
the plug for 30min;
2. If there's still malfunction,
please contact after-sales
service.
1. Re-energize the unit after
turning it off and pulling out the
plug for 30min;
2. If there's still malfunction,
please contact after-sales
service.
1. Re-energize the unit after turning
it off and pulling out the plug for
30min;
2. If there's still malfunction, please
contact after-sales service.
1. Re-energize the unit after turning
it off and pulling out the plug for
30min;
2. If there's still malfunction, please
contact after-sales service.
1. Re-energize the unit after turning
it off and pulling out the plug for
30min;
2. If there's still malfunction, please
contact after-sales service.