4. OPERATION GUIDE

4.3. OTHER FUNCTIONS AND FEATURES

WARNING ALARM
If the drain bucket is full or not correctly inserted for more than 3 minutes, a buzzer will go off for 10
seconds to remind you to empty the bucket or to properly put it back in the unit.
AUTOMATIC STOP
If the drain bucket is full, removed or not correctly inserted in the unit, or if the ambient humidity is 5 %
lower than the set humidity, the dehumidifier will automatically stop operating.
MEMORY FUNCTION
This function ensures that user settings are not lost in the event of a power outage. When power is
restored, the unit will resume operation using the memorized settings.
AUTOMATIC DEFROSTING
When frost builds up on the evaporator coils, the compressor stops and the fan continues to operate
until the frost completely disappears.
"FULL" INDICATOR
This indicates that the drain buc ket is currently full, removed or not correctly inserted.
"FILTER" INDICATOR
When the dehumidifier reaches 250 hours of operation, the Filter indicator will light up to remind the
user to clean the air filter.